![EverFocus ENVR8304D Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/everfocus/envr8304d/envr8304d_user-manual_2443441089.webp)
ENVR8304D-8CH / ENVR8304E-8CH
80
Output Type:
Select an output type when an alarm is triggered.
Timeout: Select this option and then set up the Timeout Duration in the field below, the
alarm output will last for the setup duration time (10 ~ 150 seconds).
Permanent: Alarm will remain active until the user presses the “Enter” key on the IR
Remote Control or resets the alarm remotely.
Transparent: Alarm output remains as long as the alarm input is active.
Trans + Timeout: Alarm output continues until event ends, then continues for the setup
duration time (10 ~ 150 seconds).
Timeout Duration:
This function only appears when you select
Timeout
or
Trans + Timeout
options in the Output Type drop-down list. Select a duration time for the motion event. The
alarm output will last for the setup duration time between 10 and 150 seconds.
Apply To:
Click the button to apply the same settings to the desired cameras.