4 For Professional Technical Support call 1-844-241-5521
:
All work must be performed by a qualified
pool professional, and must conform to all national, state,
and local codes.
Follow all local electrical and safety codes,
along with the National Electrical Code (NEC). In addition, all
Occupational Safety and Health Administration (OSHA)
guidelines must be followed.
:
Risk of harm
. Pumps improperly sized or
installed or used in applications other than for which the
pump was intended can result in severe personal injury or
death. These risks may include but not be limited to electric
shock, fire, flooding, suction entrapment or severe injury or
property damage caused by a structural failure of the pump
or other system component.
:
To minimize the risk of injury due to
suction entrapment hazard:
Pools and spas should utilize a minimum of two drains
per pump.
A properly installed and secured ANSI/ASMEA112.19.8
approved anti-entrapment suction cover must be used
for each drain.
Each suction cover must be installed at least three (3’)
feet apart, as measured from the nearest point to nearest
point.
Regularly inspect all covers for cracks, damage and
advanced weathering.
If a cover becomes loose, cracked, damaged, broken or is
missing, close the pool or spa immediately, shut off the
pump, post a notice and keep the pool or spa closed until
an appropriate certified cover is properly installed.
Replace drain covers as necessary. Drain covers
deteriorate over time due to exposure to sunlight, pool
chemicals and weather.
Avoid getting hair, limbs or body in close proximity to any
suction cover, pool drain or outlet.
Disable suction outlets or reconfigure into return inlets.
:
Install to provide drainage of compartment for
electrical components.
:
These instructions contain information for a
variety of pump models and therefore some instructions
may not apply to a specific model. All models are intended
for use in swimming pool applications. The pump will
function correctly only if it is properly sized to the specific
application and properly installed.
:
Electrical controls such as on/off switches,
timers, and control systems, etc. should be properly
installed to allow the operation (start-up, shut-down, or
servicing) of any pump or filter without requiring the user to
place any portion of his/her body over or near the pump
strainer lid or filter lid. Such installation should allow the
user to stand clear of the filter and pump during system
start-up, shut down or servicing of the system.
Never open the inside of the drive motor enclosure.
There is a capacitor bank that holds a 230 VAC charge
even when there is no power to the unit.
The pump is not submersible. The pump is designed for
use with chlorinated pools only. For use with other
applications, contact customer service.
The pump is capable of high flow rates; use caution
when installing and programming to limit pumps
performance potential with old or questionable
equipment.
This appliance is not intended for use by persons
(including children) of reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning the use of the appliance by a
person responsible for their safety.
:
Before pressure testing, make the
following safety checks:
Check all clamps, bolts, lids, and system accessories
before testing.
Release all air in system before testing.
Tighten pump trap lids to 30 ft. lbs. (4.1 kg-m) torque for
testing.
Water pressure for test must be less than 25 PSI (7.5
kg/cm
2
).
Water temperature for test must be less than 100° F
(38 ° C).
Limit test to 24 hours. After test, visually check system to
be sure it is ready for operation. Remove trap lid and
retighten hand tight only.
NOTICE
: These testing parameters apply only to the models
described here in. For other equipment, consult the
manufacturer.