background image

 

4                       For Professional Technical Support call 1-844-241-5521 

 

 

 

All work must be performed by a qualified 

pool professional, and must conform to all national, state, 
and local codes.

   

 

 

Follow  all  local  electrical  and  safety  codes, 

along with the National Electrical Code (NEC). In addition, all 
Occupational  Safety  and  Health  Administration  (OSHA) 

guidelines must be followed.

 

 

 

Risk of harm

. Pumps improperly sized or 

installed or used in applications other than for which the 
pump was intended can result in severe personal injury or 
death. These risks may include but not be limited to electric 
shock, fire, flooding, suction entrapment or severe injury or 

property damage caused by a structural failure of the pump 
or other system component.

 

 

 

To minimize the risk of injury due to 

suction entrapment hazard:

 

Pools and spas should utilize a minimum of two drains 
per pump. 

 

A properly installed and secured ANSI/ASMEA112.19.8 

approved anti-entrapment suction cover must be used 
for each drain. 

 

Each suction cover must be installed at least three (3’) 
feet apart, as measured from the nearest point to nearest 
point. 

 

Regularly inspect all covers for cracks, damage and 
advanced weathering. 

 

If a cover becomes loose, cracked, damaged, broken or is 
missing, close the pool or spa immediately, shut off the 
pump, post a notice and keep the pool or spa closed until 

an appropriate certified cover is properly installed. 

 

 Replace drain covers as necessary. Drain covers 
deteriorate over time due to exposure to sunlight, pool 
chemicals and weather. 

 

 Avoid getting hair, limbs or body in close proximity to any 

suction cover, pool drain or outlet. 

 

Disable suction outlets or reconfigure into return inlets. 

 

 

Install to provide drainage of compartment for 

electrical components.

 

 

These instructions contain information for a 

variety of pump models and therefore some instructions 
may not apply to a specific model. All models are intended 

for use in swimming pool applications. The pump will 
function correctly only if it is properly sized to the specific 
application and properly installed.

 

 

Electrical controls such as on/off switches, 

timers, and control systems, etc. should be properly 

installed to allow the operation (start-up, shut-down, or 
servicing) of any pump or filter without requiring the user to 
place any portion of his/her body over or near the pump 
strainer lid or filter lid. Such installation should allow the 
user to stand clear of the filter and pump during system 

start-up, shut down or servicing of the system.

 

Never open the inside of the drive motor enclosure. 
There is a capacitor bank that holds a 230 VAC charge 
even when there is no power to the unit. 

 

The pump is not submersible. The pump is designed for 

use with chlorinated pools only. For use with other 
applications, contact customer service. 

 

The pump is capable of high flow rates; use caution 
when installing and programming to limit pumps 
performance potential with old or questionable 

equipment. 

 

This appliance is not intended for use by persons 
(including children) of reduced physical, sensory or 
mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or 

instruction concerning the use of the appliance by a 
person responsible for their safety.

 

 

Before pressure testing, make the 

following safety checks:

 

Check all clamps, bolts, lids, and system accessories 
before testing. 

 

Release all air in system before testing. 

 

Tighten pump trap lids to 30 ft. lbs. (4.1 kg-m) torque for 
testing. 

 

Water pressure for test must be less than 25 PSI (7.5 
kg/cm

2

). 

 

Water temperature for test must be less than 100°  F   
(38 ° C). 

 

Limit test to 24 hours. After test, visually check system to 

be sure it is ready for operation. Remove trap lid and 
retighten hand tight only. 

NOTICE

: These testing parameters apply only to the models 

described here in. For other equipment, consult the 
manufacturer. 

 

 
 
 
 
 

 

Содержание SPP15002

Страница 1: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 241 5521 HOMEDEPOT COM ...

Страница 2: ...product covered by this warranty This Limited Warranty does not cover products which have been damaged as a result of an accident misuse abuse negligence alteration improper installation or maintenance or failure to operate in accordance with the instructions supplied with the products or operational failures caused by corrosion rust or other foreign materials in the system Requests for service un...

Страница 3: ...trapping the swimmer underwater This hazard is present when the drain cover is missing broken or the cover flow rating is not high enough for the pump or pumps Evisceration Disembowelment When a person sits on an open pool particularly a child wading pool or spa outlet and suction is applied directly to the intestines causing severe intestinal damage This hazard is present when the drain cover is ...

Страница 4: ...ore some instructions may not apply to a specific model All models are intended for use in swimming pool applications The pump will function correctly only if it is properly sized to the specific application and properly installed Electrical controls such as on off switches timers and control systems etc should be properly installed to allow the operation start up shut down or servicing of any pum...

Страница 5: ...ble pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity TOOLS REQUIRED Phillips Screwdriver Flathead Screwdriver Wrench Safety Goggles Pipe wrench Hacksaw Tape Measure Thread Tape PVC g...

Страница 6: ...or s rated ambient temperature whenever the pump is running Be solid Level Rigid Vibration free To reduce vibration and pipe stress bolt pump to mount Allow pump suction inlet height to be as close to water level as possible Pump will not lift water more than 10 ft 3 m Allow use of short direct suction pipe To reduce friction losses Allow for gate valves in suction and discharge piping Have adequa...

Страница 7: ... swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose Follow the guidelines below for a pump installation which minimizes risk to users of pools spas and hot tubs Entrapment Protection The pump suction system must provide protection against the hazard of suction entrapment or hair entrapment entanglement Suction Outlet Covers All suction outlet covers must be mainta...

Страница 8: ...SI Specifications for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirl pool Bath tub Applications Fittings Fittings restrict flow for best efficiency use fewest possible fittings but at least two suction outlets Avoid fittings which could cause an air trap Pool fittings must conform to International Association of Plumbing and Mechanical Officials IAPMO standards Use only non ent...

Страница 9: ... the motor end cover Flip the switch to 115 Volt Re install the motor end cover Pump must be permanently connected to circuit Table I gives correct wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring wire and circuit breaker sizes If unsure how to do this or if this is confusing...

Страница 10: ...he O ring with a non internally lubricated O ring you may need to apply a silicone based lubricant Clean and inspect O ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover Tighten trap cover by hand only no wrenches Pump should prime now Priming time will depend on vertical length of suction lift and horizontal length of suction piping If pump does not prime with...

Страница 11: ...nd system for shut down 2 Follow filter manufacturer s instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or deterioration over the shut down period Have a qualified service man repair wiring as needed 4 Inspect and tighten all water tight connections 5 Open all valves in suction and return piping 6 Remove any winterizing plugs in piping system 7 Drain all anti ...

Страница 12: ...screw driver BY THE HANDLE and short capacitor terminals together Do not touch metal screw driver blade or capacitor terminals If in doubt consult a qualified electrician 5 Remove motor end cover Being careful not to touch capacitor terminals loosen capacitor clamp and move capacitor to one side 6 Hold shaft with 7 16 in open end wrench on motor shaft flats 7 Unscrew impeller from shaft turn count...

Страница 13: ... 11 Prime pump according to instructions in Priming Pump Risk of electric shock Can shock burn or kill Disconnect power before working on pump or motor Read and understand safety and operating instructions in this manual before doing any work on pump Only qualified personnel should electrically test pump motor Problem Possible Cause Corrective Action Pump will not prime The suction piping leaks or...

Страница 14: ... fuse or tripped breaker Replace the fuse or reset the circuit breaker The pump may be too hot Check line voltage if less than 90 or more than 110 of rated voltage consult a licensed electrician Increase ventilation Reduce ambient temperature Tighten any loose connections The pump is experiencing mechanical troubles and noise The pipe assembly is incorrect If suction and discharge piping are not a...

Страница 15: ......

Страница 16: ...1 844 241 5521 HOMEDEPOT COM ...

Отзывы: