Risk of suction entrapment. 

Always turn off 

all power to the pool pump before installing the cover or 
working on any suction outlet. 
This pump produces high levels of suction and creates a 

strong vacuum at the main drain at the bottom of your pool or 
spa. This suction is so strong that it can trap adults or 
children under water if they come in close proximity to a pool 
or spa drain or a loose or broken drain cover or grate. 
Stay off the main drain and away from all suction outlets! 

   

 

Risk of hazardous pressure.

 Stand clear of 

pump and filter during start-up. Pool and spa circulation 
systems operate under high pressure. When any part of the 
circulating system (i.e. locking ring, pump, filter, valves, 

etc.) is serviced, air can enter the system and become 
pressurized.

 

Pressurized air can cause the pump housing cover filter 
lid and valves to violently separate which can result in 
severe personal injury or death. 

 

Filter tank lid and strainer cover must be properly 
secured to prevent violent separation. 

 

Stand clear of all circulation system equipment when 
turning on or starting up pump. 

 

Before servicing pool and spa equipment, make note of 

the filter pressure. Be sure that all controls are set to 
ensure the system cannot inadvertently start during 
service. Turn off all power to the pump. 

 

Place filter manual air relief valve in the open position 
and wait for all pressure in the system to be relieved. 

 

Before starting the system, fully open the manual air 
relief valve and place all system valves in the “open” 
position to allow water to flow freely from the pool and 
spa back to the pool or spa. Stand clear of all pool and 
spa equipment and start the pump. 

 

Do not close filter manual air relief valve until all 
pressure has been discharged from the valve and a 
steady stream of water appears. Observe filter pressure 
gauge and be sure it is not higher than the pre-service 
condition. 

 

Risk of suction entrapment. The use of 

unapproved covers or allowing use of the pool or spa when 
covers are missing, cracked or broken can result in body or 
limb entrapment, hair entanglement, body entrapment, 
evisceration and/or death.

 

Limb Entrapment:

 When a limb is sucked or inserted 

into an opening resulting in a mechanical bind or 
swelling. This hazard is present when a drain cover is 
missing, broken, loose, cracked or not properly secured. 

 

Hair Entanglement:

 When the hair tangles or knots in 

the drain cover, trapping the swimmer underwater. This 

hazard is present when the flow rating of the cover is too 
small for the pump or pumps. 

 

Body Entrapment:

 When a portion of the body is held 

against the drain cover trapping the swimmer 
underwater. This hazard is present when the drain cover 

is missing, broken or the cover flow rating is not high 
enough for the pump or pumps. 

 

Evisceration/Disembowelment:

 When a person sits on 

an open pool (particularly a child wading pool) or spa 
outlet and suction is applied directly to the intestines, 
causing severe intestinal damage. This hazard is present 

when the drain cover is missing, loose, cracked, or not 
properly secured. 

 

Mechanical Entrapment:

 When jewelry, swimsuit, hair 

decorations, finger, toe or knuckle is caught in an 
opening of an outlet or drain cover. This hazard is present 

when the drain cover is missing, broken, loose, cracked, 
or not properly secured. 

NOTICE:

 All suction plumbing must be installed in 

accordance with the latest national and local codes for 
swimming pools, spas and hot tubs, including NSPI 
standards and CPSC guidelines.

 

 

 

 

 

ALWAYS  disconnect  the  power  to  the  pump 

before servicing.

 

 

 

Risk of harm.

 A clearly labeled emergency 

shut-off switch for the pool pump and spa jet pump must 
be in an easily accessible, obvious place near the pool or 

spa. Make sure bathers know where it is and how to use it in 
case of emergency.

 

Risk of harm. 

To reduce the risk of injury, do 

not permit children to use this product unless they are 
closely supervised at all times.

 

Risk of hazardous pressure.

 Pool and spa 

circulation systems operate under high pressure. 
Incorrectly installed or tested equipment may fail, causing 
severe injury or property damage. Read and follow 
instructions in owner’s manual when installing and 
operating equipment. Have a trained pool professional 

perform all pressure tests.

 

Do not connect system to a high pressure or city water 
system. 

 

Use equipment only in a pool or spa installation. 

 

Trapped air in system can cause explosion. BE SURE all 

air is out of system before operating or testing 
equipment. See hazardous pressure warning below. Do 
not use compressed air to clean, test, or purge 
equipment for winter. 

 

 

Risk of electric shock

. Can shock, burn or kill. 

Connect only to a branch circuit protected by a ground-fault 
circuit-interrupter (GFCI). Contact a qualified electrician if 

you cannot verify that the circuit is protected by a GFCI. This 
unit must be connected only to a supply circuit that is 
protected by a ground fault circuit-interrupter (GFCI). Such a 
GFCI should be provided by the installer and should be tested 
on a routine basis. To test the GFCI, push the test button. The 

GFCI should interrupt power. Push the reset button. Power 
should be restored. If the GFCI fails to operate in this manner, 
the GFCI is defective. If the GFCI interrupts power to the 
pump without the test button being pushed, a ground current 
is flowing, indicating the possibility of an electric shock. Do 

not use this pump. Disconnect the pump and have the 
problem corrected by a qualified service representative 
before using.

 

 

Содержание SPP15002

Страница 1: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 241 5521 HOMEDEPOT COM ...

Страница 2: ...product covered by this warranty This Limited Warranty does not cover products which have been damaged as a result of an accident misuse abuse negligence alteration improper installation or maintenance or failure to operate in accordance with the instructions supplied with the products or operational failures caused by corrosion rust or other foreign materials in the system Requests for service un...

Страница 3: ...trapping the swimmer underwater This hazard is present when the drain cover is missing broken or the cover flow rating is not high enough for the pump or pumps Evisceration Disembowelment When a person sits on an open pool particularly a child wading pool or spa outlet and suction is applied directly to the intestines causing severe intestinal damage This hazard is present when the drain cover is ...

Страница 4: ...ore some instructions may not apply to a specific model All models are intended for use in swimming pool applications The pump will function correctly only if it is properly sized to the specific application and properly installed Electrical controls such as on off switches timers and control systems etc should be properly installed to allow the operation start up shut down or servicing of any pum...

Страница 5: ...ble pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity TOOLS REQUIRED Phillips Screwdriver Flathead Screwdriver Wrench Safety Goggles Pipe wrench Hacksaw Tape Measure Thread Tape PVC g...

Страница 6: ...or s rated ambient temperature whenever the pump is running Be solid Level Rigid Vibration free To reduce vibration and pipe stress bolt pump to mount Allow pump suction inlet height to be as close to water level as possible Pump will not lift water more than 10 ft 3 m Allow use of short direct suction pipe To reduce friction losses Allow for gate valves in suction and discharge piping Have adequa...

Страница 7: ... swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose Follow the guidelines below for a pump installation which minimizes risk to users of pools spas and hot tubs Entrapment Protection The pump suction system must provide protection against the hazard of suction entrapment or hair entrapment entanglement Suction Outlet Covers All suction outlet covers must be mainta...

Страница 8: ...SI Specifications for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirl pool Bath tub Applications Fittings Fittings restrict flow for best efficiency use fewest possible fittings but at least two suction outlets Avoid fittings which could cause an air trap Pool fittings must conform to International Association of Plumbing and Mechanical Officials IAPMO standards Use only non ent...

Страница 9: ... the motor end cover Flip the switch to 115 Volt Re install the motor end cover Pump must be permanently connected to circuit Table I gives correct wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring wire and circuit breaker sizes If unsure how to do this or if this is confusing...

Страница 10: ...he O ring with a non internally lubricated O ring you may need to apply a silicone based lubricant Clean and inspect O ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover Tighten trap cover by hand only no wrenches Pump should prime now Priming time will depend on vertical length of suction lift and horizontal length of suction piping If pump does not prime with...

Страница 11: ...nd system for shut down 2 Follow filter manufacturer s instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or deterioration over the shut down period Have a qualified service man repair wiring as needed 4 Inspect and tighten all water tight connections 5 Open all valves in suction and return piping 6 Remove any winterizing plugs in piping system 7 Drain all anti ...

Страница 12: ...screw driver BY THE HANDLE and short capacitor terminals together Do not touch metal screw driver blade or capacitor terminals If in doubt consult a qualified electrician 5 Remove motor end cover Being careful not to touch capacitor terminals loosen capacitor clamp and move capacitor to one side 6 Hold shaft with 7 16 in open end wrench on motor shaft flats 7 Unscrew impeller from shaft turn count...

Страница 13: ... 11 Prime pump according to instructions in Priming Pump Risk of electric shock Can shock burn or kill Disconnect power before working on pump or motor Read and understand safety and operating instructions in this manual before doing any work on pump Only qualified personnel should electrically test pump motor Problem Possible Cause Corrective Action Pump will not prime The suction piping leaks or...

Страница 14: ... fuse or tripped breaker Replace the fuse or reset the circuit breaker The pump may be too hot Check line voltage if less than 90 or more than 110 of rated voltage consult a licensed electrician Increase ventilation Reduce ambient temperature Tighten any loose connections The pump is experiencing mechanical troubles and noise The pipe assembly is incorrect If suction and discharge piping are not a...