6 For Professional Technical Support call 1-844-241-5521
MATERIALS REQUIRED (NOT INCLUDED)
SPECIFICATIONS
Power supply
SPP15002: 115V/230V, 60 HZ., 20 Amp Circuit
Liquid temp. range
32 to 100° F (0- 38° C)
Discharge size
1 -1/2 in. NPT
:
For quick disconnect pipe connections, use the 1-1/2 in. Slip Half Union Kit included with the pump. Only qualified, licensed
personnel should install pump and wiring.
Pump mount must:
Be located away from corrosive or flammable liquids.
Have enough ventilation to maintain air temperature at less than the maximum ambient temperature rating (Max. Amb.) listed on the motor
model plate. If this pump is installed in an enclosure/pump house, the enclosure must have adequate ventilation and air circulation to keep the
temperature in the enclosure at or below the motor’s rated ambient temperature whenever the pump is running.
Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.)
Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10 ft. (3 m).
Allow use of short, direct suction pipe (To reduce friction losses).
Allow for gate valves in suction and discharge piping.
Have adequate floor drainage to prevent flooding.
Be protected from excess moisture.
Allow adequate access for servicing pump and piping.
Risk of fire and burns.
Can cause severe injury, property damage or death. Motors run at high temperatures. To reduce the risk of fire, do not allow
leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for 20 minutes before trying
to work on it.
:
When connecting pipe to pump with union half, use PTFE tape between pipe and union adapter. Union collar to pump should
be assembled dry and hand-tight.