14 For Professional Technical Support call 1-844-241-5521
Problem
Possible Cause
Corrective Action
The pump may be running too
slow.
There is an error in the wiring or the
voltage is not set correctly.
Check voltage at motor terminals and at meter while pump is
running. If low, see wiring instructions or consult power
company. Check for loose connections.
The pump suddenly stops
working.
There is a blown fuse or tripped breaker.
Replace the fuse or reset the circuit breaker.
The pump may be too hot.
Check line voltage; if less than 90% or more than 110% of
rated voltage consult a licensed electrician.
Increase ventilation.
Reduce ambient temperature.
Tighten any loose connections.
The pump is experiencing
mechanical troubles and noise.
The pipe assembly is incorrect.
If suction and discharge piping are not adequately supported,
pump assembly will be strained. See Installation.
The pump is not mounted correctly.
Do not mount pump on a wooden platform! Securely mount on
concrete platform for quietest performance.
Содержание SPP15002
Страница 15: ......
Страница 16: ...1 844 241 5521 HOMEDEPOT COM ...