Salt Bath 709 / 718 / 818
Installation and Operating Manual
North American Model
June 2019
Page
11
of
36
Immersion Thermocouple (#3, upper jack) - Installation
The purpose of the Immersion thermocouple is to measure the temperature of the salt bath itself. That is to say that the immersion thermocouple is
immersed into the molten salts during operation. It is the Immersion thermocouple that you should use when performing your heat treating as it gives the
actual temperature of the salt bath. The Immersion thermocouple is supplied with a mount.
The Immersion thermocouple consists of two items: Type K thermocouple, (13.75” long on SB 709 and 18” long on SB 718 and SB 818), 3/16” diameter
Inconel sheath assembly and a 30”, Type K lead assembly. Both assemblies are supplied with standard sized male and female connectors. Note the
grounding wire connector on the thermocouple assembly and the green grounding wire included with the lead assembly.
The immersion thermocouple is also supplied with thermocouple mount. The thermocouple mount properly places the immersion thermocouple within
the pot and away from the pot wall. The thermocouple mount is designed to be easily removable from the pot lip.
Salt Bath Immersion Thermocouple Assembly & Mount
Immersion Thermocouple Assembly SB 709 Part #11647.310
Immersion Thermocouple Assembly SB 718 & SB 818 Part #11647.310
Immersion Thermocouple Mount Replacement Part #11647.320
Salt Bath Immersion Thermocouple Lead Assembly
Immersion Thermocouple Lead Assembly Replacement Part #11647.312
Plug the male thermocouple plug into the female lead plug.
Attach the thermocouple lead assembly green ground wire to
the thermocouple ground connector as shown. Snug is good.
Place the immersion thermocouple within the mount and place the mount
on the lip of the salt pot as shown. Draw the mount ears tight to the pot
and tighten the outer 2 nuts as shown.