background image

Salt Bath 709 / 718 / 818 

Installation and Operating Manual 

North American Model

 

 June 2019 

 

Page 

8

 of 

36

 

 

 

Thermocouple Installation 

 
The Salt Bath kiln uses 3 thermocouples for control. The Over-Temp (high limit) has been installed at the factory. The Chamber and Immersion thermocouples must 
be installed. 
 

Over-Temp Thermocouple (#1, lower jack) – Installed at Factory 

 
The purpose of the over-temp thermocouple is to stop the heating process if the kiln chamber exceeds the programmed temperature by 300°F (149°C). 
The over-temp thermocouple is installed at the factory and remains in place at all times and is not movable. 
 
 

 

 
 
The Over-Temp thermocouple is a Type K thermocouple, 1/8” 
diameter Inconel sheath, bent at 90°. Supplied with standard 
sized male thermocouple connector. 
 
Note the grounding wire connected to the Inconel sheath. This 
ground wire will be connected to the control panel. 
 
 

 

 

Salt Bath Over-Temp (High Limit) Thermocouple Assembly 

Over-Temp Thermocouple Assembly Replacement Part #11647.315 

 
 
 
 
 

 
 
 
 
The Over-Temp thermocouple properly installed. 
 
Note that the over-temp thermocouple is plugged into the #1 
thermocouple jack (lower jack). Do not position the over-temp 
thermocouple at any other jack than the #1 jack. 
 
The over-temp thermocouple should be inserted into the firing 
chamber as far as possible and should remain there. 
 
Note also that the green ground lead for the over-temp 
thermocouple is secured to the labeled ground connection 
located on the control panel. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Over-Temp Thermocouple Properly Installed 

 
 
 
 
 
 

Содержание Salt Bath 709

Страница 1: ...and Floor Easily Replaced 26 Charging Filling Your Salt Pot Salt Bath Maintenance 27 Put on Your Personal Protective Equipment 16 Salt Leaks 28 Turn on Any Ventilation Systems 16 Replacement Parts Li...

Страница 2: ...ach Explosion Pressure Release Hazard This symbol alerts you to potential explosion and pressure release hazards Electric Shock Hazard This symbol alerts you to potential electric shock hazards Burn H...

Страница 3: ...es The kilns operating voltage printed on the kilns nameplate must match the applied voltage actual electrical service voltage If it does not do not install or operate the kiln as potential electrical...

Страница 4: ...ork piece holders must be constructed of carbon steels or stainless steels Do not attempt to heat treat any coated or plated steel Coatings and plating s include but are not limited to zinc galvanized...

Страница 5: ...gn that you insert the Immersion thermocouple into the salt bath and control from the Immersion thermocouple Never fire a kiln unattended Do not attempt to insert any thermocouples or any other device...

Страница 6: ...he ground connection at the salt pot is prone to corrosion with use Periodic inspection shall be made to ensure a sound electrical connection between the salt pot salt pot grounding lug hardware and t...

Страница 7: ...North American Model June 2019 Page 7 of 36 Make a Square by Placing Frame Angles as Shown Attach Each Leg Using the Included Nuts and Bolts as Shown Place Plastic Feet on Each Leg as Shown Completed...

Страница 8: ...thermocouple 1 8 diameter Inconel sheath bent at 90 Supplied with standard sized male thermocouple connector Note the grounding wire connected to the Inconel sheath This ground wire will be connected...

Страница 9: ...Inconel sheath assembly and a 30 Type K lead assembly Both assemblies are supplied with standard sized male and female connectors Note the grounding wire connector on the thermocouple assembly and th...

Страница 10: ...10 of 36 Chamber thermocouple assemblies properly assembled Insert the Chamber thermocouple into the chamber through the left rear corner as shown An insertion hole has been provided Plug the Chamber...

Страница 11: ...ector on the thermocouple assembly and the green grounding wire included with the lead assembly The immersion thermocouple is also supplied with thermocouple mount The thermocouple mount properly plac...

Страница 12: ...stud as shown At this point all 3 thermocouple grounds are attached to the ground stud Salt Pot Ground Strap Installation to Control Panel The salt pot is grounded to the control panel via a ground st...

Страница 13: ...r other contaminants before using Salt pots should include a 0 250 hole 0 750 from the top of the pot This hole is designed to fit 20 hardware for the grounding lug Salt Pot grounding lug hardware att...

Страница 14: ...ed and centered push the Over temp and Chamber thermocouples back into the chamber As noted earlier you may elect to allow the chamber thermocouple to make contact with the salt pot or not If not pull...

Страница 15: ...d Strap Installation to Salt Pot Grounding Lug Connect the salt pot grounding strap to the salt pot ground lug as shown The connection should be tight We like to place the salt pot grounding lug point...

Страница 16: ...no more than chamber depth We want to keep the surface of the molten salt at or below the bottom of the lid The pot does should extend beyond the lid but keeping the molten salt level within the boun...

Страница 17: ...time that you will perform your heat treating process The amount of hold time depends upon the amount of time you expect your heat treat session to last Keep in mind that you can always abort the hea...

Страница 18: ...control from that thermocouple Be sure at least 1 of the Immersion thermocouple is immersed within the molten salt If it isn t yet continue to add salts until it does and then proceed with this step A...

Страница 19: ...you do plan to perform a heat treat session please read the following section entitled Standard Everyday Use for operational information Proper Shutdown When shutting down the salt bath heat treat kil...

Страница 20: ...examine the firing data for correctness prior to committing to the process When developing a heat treat program we recommend that you not create any heating rates faster than 1000 F per hour Heating t...

Страница 21: ...esulting in the molten salts being violently expelled out of the salt pot and into the surrounding area This presents a burn and fire hazard as well as potential personal injury or death Immersion The...

Страница 22: ...uple is being used for control After about 10 minutes of screen inactivity a large text screen appears and Immersion is prominently displayed You may switch back and forth between the Chamber and Imme...

Страница 23: ...s to be steel wire Whatever suspension method you do decide on it must be made of steel We would mention that we are not aware of any useful technique that simply places the work piece into the salt b...

Страница 24: ...mbustible material We would suggest that you use care to avoid allowing dragout to run down the outside of the salt pot The refractory fiber gasketing material tends to stop the salts from reaching th...

Страница 25: ...enerally it s better to try to keep it off the wall and surrounded with molten salt Over Temp Thermocouple Circuit Salt bath kilns include a dedicated over temperature thermocouple circuit The role of...

Страница 26: ...Swing View allows for swiveling between a comfortable programming and use angle to a vertical position well suited for viewing at a distance across the shop We recommend placing the TAP control at the...

Страница 27: ...The salt pot ground consists of a braided ground strap that is attached at both the salt pot and control panel Keep a close eye on the end that is connected to the salt pot Look for any loose connecti...

Страница 28: ...lt pot leak may result in a short circuit with a corresponding trip of breakers or fuses It s for this reason that we supply grounds on the entire kiln chamber control panel thermocouples and salt pot...

Страница 29: ...els SB 709 and SB 718 Repair Ring 07276 000 Elemented Brick Section for model 818 Repair Ring 07276 005 Lid for models SB 709 and SB 718 No Hole 00342 300 Lid for models SB 709 and SB 718 for 4 Pot Ho...

Страница 30: ...Model June 2019 Page 30 of 36 Du Bois Chemicals Co gives the following melting point and working temperature range for Nu Sal as Melting Point 1230 F 665 C Working Temperature Range 1300 1650 F 704 89...

Страница 31: ...Salt Bath 709 718 818 Installation and Operating Manual North American Model June 2019 Page 31 of 36 Nu Sal SDS page 2 of 7...

Страница 32: ...Salt Bath 709 718 818 Installation and Operating Manual North American Model June 2019 Page 32 of 36 Nu Sal SDS page 3 of 7...

Страница 33: ...Salt Bath 709 718 818 Installation and Operating Manual North American Model June 2019 Page 33 of 36 Nu Sal SDS page 4 of 7...

Страница 34: ...Salt Bath 709 718 818 Installation and Operating Manual North American Model June 2019 Page 34 of 36 Nu Sal SDS page 5 of 7...

Страница 35: ...Salt Bath 709 718 818 Installation and Operating Manual North American Model June 2019 Page 35 of 36 Nu Sal SDS page 6 of 7...

Страница 36: ...Salt Bath 709 718 818 Installation and Operating Manual North American Model June 2019 Page 36 of 36 Nu Sal SDS page 7 of 7...

Отзывы: