Salt Bath 709 / 718 / 818
Installation and Operating Manual
North American Model
June 2019
Page
12
of
36
Position the immersion thermocouple under the bracket and tighten
the inner 2 nuts as shown. The immersion thermocouple is now set-
up. To remove it from the pot lip just pull off the mount.
Plug the Immersion thermocouple into the #3 jack (upper jack)
and attach the ground onto the ground stud as shown.
At this point all 3 thermocouple grounds are attached to the ground stud.
Salt Pot Ground Strap Installation to Control Panel
The salt pot is grounded to the control panel via a ground strap which must be installed. The salt pot ground is designed to safely dissipate any electrical energy
finding its way to the salt pot itself. It must be connected during operation of the salt bath kiln.
Salt Pot Ground Strap – 18” eye to eye
Salt Pot Ground Strap Replacement Part #08298.235
Attach the salt pot ground strap to the upper
ground lug on the rear of the control panel as shown.