Page 30/34
1.
400 V GRID CONNECTION TERMINAL BLOCK:
- Ground GRID: Max section: 95 mm
²
, allows connection of the ground terminal
- Neutral GRID: Max Section: 95 mm
²
, allows connection of the neutral terminal
- Ph1 GRID: Max section: 95 mm
²
, allows connection of the phase 1 terminal
- Ph2 GRID: Max section: 95 mm
²
, allows connection of the phase 2 terminal
- Ph3 GRID: Max section: 95 mm
²
, allows connection of the phase 3 terminal
2.
ARU EXT:
Maximum section: 2,5 mm
²
, allows connection of an external ARU button, voltage 24
Vdc, 10 mA max current.
3.
CAN:
Maximum section 2,5 mm
²
, can connect the CAN communication (terminal of 1 input/3
outputs), voltage 10 Vdc, 50 mA max current.
4.
BUS CAN shield:
Maximum section 2,5 mm
²
, to connect the CAN communication cable shield.
5.
24 Vdc:
(for floor sensor) Maximum section 2,5 mm
²
, Orange = +24 V, Blue = GND, 24 Vdc voltage,
7 A max current.
6.
RS485: (
for floor sensor) Maximum section 2,5 mm
²
, allows connection of the RS485/MODBUS
communication (terminal of 1 input/3 outputs), voltage 10 Vdc, 50 mA max current.
7.
RS485 shield:
Maximum section 2,5 mm
²
, to connect the RS485 communication cable shield.
8.
SERVICE SOCKET (230 Vac):
Allows connection of the 230 Vac equipment within the limit of 6 A,
230 Vac voltage, 16 A current (protect with the circuit breaker and differential D3).
9.
230 Vac terminal block:
Max Section: 2,5 mm
²
, used to connect 230 Vac equipment within the
limit of 6 A, 230 Vac voltage, 16 A current (protect with the circuit breaker and differential D3).
10.
SATTELITES OPTION:
Max Section: 35 mm
²
, used to connect a DC satellite, 600 Vdc voltage,
125 Adc current.
11.
D9:
E/F 230 Vac Home Plug head Circuit Breaker. 16 A, curve C (Circuit B 30 mA
differential type A).
12.
D3:
230 Vac control head circuit breaker, 16 A, curve C (Circuit B 30 mA differential type
A).
13.
D1'':
Circuit breaker position sensor D1.
14.
D1'' ':
Transmission coil that allows D1 to deactivate.
15.
D1:
power head breaker, 100 A, 4-pole, D-curve.
16.
D7 ':
Differential circuit breaker 30 mA, type A APR for AC output 43 kW.
17.
D7:
thermal magnetic circuit breaker 80 A, curve D for the 43 kW AC output (D7 is supplied with
D1 series).
18.
K7:
power contactor, AC1/75 A 4-pole, that cuts power to the 43 kW AC.
19.
K9:
power contactor, AC1/26 A 3-pole, that cuts off power to the single-phase E/F home socket.
Содержание Troniq
Страница 1: ...D000782AA6 EVBox Troniq Installation Manual ...
Страница 27: ...Page 27 34 8 APPENDIX 3 DIMENSIONS Charger dimensions without Auxiliary power cabinet APC ...
Страница 28: ...Page 28 34 Charger dimensions with Auxiliary power cabinet APC ...
Страница 29: ...Page 29 34 9 APPENDIX 4 CONNECTION TERMINALS DETAILS POWER AND COMMUNICATION ...