– 12 –
Temperature & Humidity Sensor Z-Wave Plus can be associated with other devices.
Group No.
Description
Commands
Max supported
Nodes
1
Lifeline
DEVICE_RESET_LOCALLY_NOTIFICATION,
BATTERY_REPORT,
SENSOR_MULTILEVEL_REPORT,
1
2
Temperature
SENSOR_MULTILEVEL_REPORT
5
9. Association
11. Configuration
Temperature & Humidity Sensor Z-Wave Plus can be configured during runtime.
Parameter
number
Size
in Byte
Name
Description
1
1
Temperature on
Change Reporting
0x00 No on change reporting (only time-based reports)
0x01 – 0x32
report if temperature changed by delta = 0,1°C…5,0°C
default: 0x05
2
1
Humidity on Change
Reporting
0x00 No on change reporting (only time-based reports).
0x01-0x0A report if humidity changed by delta = 1% …10%
default: 0x05
3
1
Unit Temperature
0x00 Temperature reports in Celsius
0x01 Temperature reports in Fahrenheit
default: 0x00
4
1
Resolution Tempe-
rature
0x00 No resolution (example 22°C)
0x01 1/10 resolution (example 22.3°C)
0x02 1/100 resolution (example 22.35°C)
default: 0x01
5
1
Resolution Humidity 0x00 No resolution (example 33%)
0x01 1/10 resolution (example 33.4%)
0x02 1/100 resolution (example 33.45%)
default: 0x00
Temperature & Humidity Sensor Z-Wave Plus battery level can be requested.
Max value 100%
Max value
0%
Resolution
25% steps
Warning level
0xFF (battery empty)
10. Battery