– 13 –
Temperature & Humidity Sensor Z-Wave Plus measures the room temperature and automatically reports sen-
sor readings to associated devices.
Per default the reporting threshold is ±0.5°C. This parameter can be altered via configuration command class.
Sensor type:
„Air Temperature“
Scale:
Celsius and Fahrenheit
Precision:
0,1 and 2
Sensor type:
„Humidity“
Scale:
Prozent and absolut
Precision:
0,1 and 2
Temperature & Humidity Sensor Z-Wave Plus measures the humidity and automatically reports sensor read-
ings to associated devices.
Per default the reporting threshold is ±5%. This parameter can be altered via configuration command class.
12. Multilevel Sensor
Sensor type:
„Dewpoint“
Scale:
Celsius and Fahrenheit
Precision:
1
Temperature & Humidity Sensor Z-Wave Plus measures the dewpoint and automatically reports sensor read-
ings every 30 minutes to associated devices .
Min interval:
10 Minutes
Max interval:
24 hours
Default interval:
60 Minutes
Resolution:
2 Minutes
Temperature & Humidity Sensor Z-Wave Plus wake up interval can be configured.
13. Wake Up