3-3
TE200S User manual
CONNECTIONS
Power
The power terminal blocks (mains and load) are cage terminal blocks.
The safety earth is connected to an M5 screw.
Control
The control terminal block has a screw connector.
This terminal block plugs in.
Fan (63A rated unit)
The fan connection (for fan-cooled units) is made by means of cage terminal blocks.
Connection details
The terminal capacities and tightening torques to be observed are given in Table 3-1.
Parameter
Power & load
Safety earth
Control
supply
Terminal capacity (mm
2
)
10 to 25
Equal to or
1.5
greater than power
cross-section
Tightening torque (Nm)
2
2
0.7
Table 3-1 TE200S solid state relay connection details
Warning !
The cross-section of the conductors to be used must comply with Standard
IEC 943.