Chapter 4 - SETTING-UP AND COMMISSIONING
4-32
584S Frequency Inverter
5) The setup parameters are now locked. Remember to use
PARAMETER SAVE
to put the password value in
non-volatile memory. If you now go back to the
CHANGE PASSWORD
menu the password value is hidden and
the display will show:
CHANGE PASSWORD
****
Example 2
Example 2
Example 2
Example 2: Accessing
: Accessing
: Accessing
: Accessing setup parameters when the password is set.
setup parameters when the password is set.
setup parameters when the password is set.
setup parameters when the password is set.
1) Access the
ENTER PASSWORD
menu. The display will show:
ENTER PASSWORD
0X0000
2) Use the up and down arrow keys to select your password.
3) Press the 'E' key to exit the
ENTER PASSWORD
menu.
4) Access the
SETUP PARAMETERS
menu to make any necessary changes.
5) When all parameter changes have been made come back to the
CLEAR PASSWORD
menu to hide the
password value and lock the setup parameters again.
Example 3
Example 3
Example 3
Example 3: Changing a previously set password
: Changing a previously set password
: Changing a previously set password
: Changing a previously set password
1) Access the
ENTER
PASSWORD
menu.
2) Use the up and down arrow keys to enter the existing password value.
3) Leave the
ENTER
PASSWORD
menu and access the
CHANGE
PASSWORD
menu.
4) Use the up and down arrow keys to select a new password value.
5) Leave the
CHANGE
PASSWORD
menu and access the
CLEAR
PASSWORD
menu.
6) Press the 'M' key to clear the password value and lock the setup parameters.
7) Remember to use
SAVE
PARAMETERS
to save the new password value in non-volatile memory.
PARAMETERS SAVE
This menu is used to save all of the drive parameters in the non-volatile memory. Press the UP arrow as instructed
on the second line of the MMI display (UP TO ACTION) to save the drive parameters.
NOTE:-
Parameters cannot be saved when the drive is unhealthy or braking (stopping). Toggle run signal to clear
alarm or wait for drive to stop before saving.
SYSTEM
Options within the System menu are described in the following paragraphs:
Reconfig O/Ps
This menu controls the function of the two user-configurable relay outputs, RELAY 1, and RELAY 2. For each
relay the following options are available:
ZERO SPEED
The relay contacts close when the drive output frequency is at 0Hz ±
0
SPEED THRESH
parameter.
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - [email protected]
Содержание 584S
Страница 122: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 173: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 174: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 175: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...