Chapter 8 - Appendices
584S Frequency Inverter
8 -27
Tag Description
Default
Min
Max
User
Setting
35
Reserved
-
-
-
-
-
36
Relay 1 configuration
Zero speed
0
5
RW
37
Relay 2 configuration
At speed
0
5
RW
38
Drive current
-
-200.00%
200.00%
RO
39
Inverter frequency
-
-100.00%
100.00%
RO
40
Enter password
0x0000
0
FFFF
RW
41
Change password
0x0000
0
FFFF
RW
42
Reserved
-
-
-
-
-
43
Framp time
1.0s
0.1s
3000.0s
RW
44
External torque limit select
Disabled
0
1
RW
45
Reserved
-
-
-
-
-
46
Reserved
-
-
-
-
-
47
Reserved
-
-
-
-
-
48
Reserved
-
-
-
-
-
49
Reserved
-
-
-
-
-
50
Reserved
-
-
-
-
-
51
Reserved
-
-
-
-
-
52
Reserved
-
-
-
-
-
53
Slip compensation
0.0Hz
0%
4.17%
RW
54
Stabilisation
0.6Hz
0%
4.17%
RW
55
Aux run
Enabled
0
1
RW
56
Aux framp
Enabled
0
1
RW
57
Aux direction
Enabled
0
1
RW
58
Drive status
-
0
FFFF
RO
59
Digital inputs
-
0
00FF
RO
60
Drive load
-
-200.00%
200.00%
RO
61
Speed setpoint
-
-100.00%
100.00%
RO
62
External torque limit
-
0%
150.00%
RO
63
Reserved
-
-
-
-
-
64
Reserved
-
-
-
-
-
65
P1 serial link enable
Enabled
0
1
RO
66
P3 serial link enabled
Enabled
0
1
RO
67
P1 GID
0
0
7
RO
68
P3 GID
0
0
7
RO
69
P1 UID
0
0
15
RO
70
P3 UID
0
0
15
RO
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - [email protected]
Содержание 584S
Страница 122: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 173: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 174: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 175: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...