Chapter 8 - Appendices
584S Frequency Inverter
8 -49
Formula 1
The first response time formula, formula 1, is given below:
Tr
RAMPTIME
d
SRAMP
SRAMP
=
× ×
×
−
2
100
200
%
%
%
%
%
This can be simplified as follows:
Tr
RAMPTIME
A
B
=
× ×
The factors A and B are given for varying values of
S RAMP %
and
d%
in the tables below:
S RAMP %
A
d%
B
0
0
0
0
10
0.046
10
3.16
20
0.067
20
4.47
30
0.084
30
5.48
40
0.100
40
6.32
50
0.116
50
7.07
60
0.131
60
7.75
70
0.147
70
8.37
80
0.163
80
8.94
90
0.181
90
9.49
100
0.200
100
10.0