Chapter 1 - Product Overview
584S
1-9
584S ( TYPE 7 )
584S ( TYPE 7 )
584S ( TYPE 7 )
584S ( TYPE 7 )
AIR FLOW CLEARANCE
Refer to figure 3.1
MOUNTING ORIENTATION
Vertical
WEIGHT
45 kW (400V)
22 kW (230V)
76 kg
55 kW (400V)
30 kW (230V)
80 kg
75 kW (400V)
37 kW (230V)
84 kg
DIMENSIONS
Refer to figure 3.1
POWER AND EARTH
(GROUND) TERMINATIONS
(a)
Supply (L1-3), Motor (M1/U-M3/W), Brake (DBR1-2)
Terminals:
Compact high current terminal blocks.
Terminals accommodate wire range 33.6 - 107.2mm
2
(2 - 4/0 AWG).
Tightening torque 20Nm, 175lb-in (14.6lb-ft).
(b)
D.C. interconnection terminals (DC+, DC-):
Compact high current terminal blocks.
Terminals accommodate wire range 33.6 - 152mm
2
(2AWG - 300kcmil (MCM)).
Tightening torque 30.5Nm, 270lb-in (22.5lb-ft).
(c)
Earth (ground)
:
Compact high current terminal blocks.
Terminals accommodate wire range 33.6 - 107.2mm
2
(2 - 4/0 AWG).
Tightening torque 22.6Nm, 200lb-in (16.7lb-ft).
CONTROL TERMINATIONS
Removable screw connectors for 0.75mm
2
wire.
Terminals will accept up to 3.3mm
2
wire (12 AWG).
Tightening torque 0.56 - 0.79Nm, 5 - 7lb-in (0.42 - 0.58lb-ft)
ENCLOSURE
IP20 (as standard), to be built into a suitable cubicle.
IP40 (with UL Type 1 top cover) Type 4, 5, 6 and 7 only, suitable for wall mounting in Europe.
EMC Specification
For EMC Specification refer to Chapter 7 The European Directives and the ‘CE’ Mark
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - [email protected]
Содержание 584S
Страница 122: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 173: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 174: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Страница 175: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...