EUROSTER 2006TXRXG
–
INSTALLATION AND OPERATION MANUAL
8
Green
–
normally open mode (COM
–
NO). It is the mainly used operation mode. While the
device operation indicator is active, the output cables are shorted.
Red
–
normally closed mode (COM
–
NC). While the device operation indicator is active, the
output cables are opened.
Caution! The factory default setting is (COM-NO).
The operating mode can be selected for 10 minutes after the receiver has been
connected to the mains!
8.
FIRST START
When inserted into the mains socket, the receiver indicates the relay operating mode. A flash
of green LED
–
normally open mode (COM-NO), a flash of red
–
normally closed mode (COM-
NC).
Any change in the status of the thermostat (switching the heating on/off) is made immediately
by the receiver, while the confirmation that the radio signal is received from the transmitter is
repeated every 15 minutes.
RADIO SIGNAL STRENGTH
The radio signal strength is indicated together with the reception of the transmitter signal.
Radio signal reception is indicated in green. LED flashing three times stands for a very strong
range, twice for a strong range, and once for sufficient range.
NO RADIO COMMUNICATION
If the communication between the thermostat and the receiver is interrupted (e.g. discharged
batteries) and if this condition lasts for 60 minutes (no response from the receiver), the
receiver switches to the frost protection mode. The heating device will be switched on every 3
hours for 20 minutes to prevent the rooms from being cooled down. At the time of re-
establishing communication (e.g. replacement of batteries), the receiver will automatically
switch the system off and resume operation.
If there is no radio communication, the green LED flashes rapidly.
CONTINUOUS OPERATION OF HEATING DEVICE (MAN)
In the event of system failure, it is possible to manually switch on the heating. Move the switch
on the RX receiver to the MAN position. Such status is indicated by a rapid flashing of the red
LED.
RECEIVER SIGNALING TABLE.
Function
Signaling
Pairing
Blue
Reception of radio signal
Green
No radio communication
Green
–
flashing
The heating/air-conditioning device is switched on
Red
Manual mode
Red
–
flashing