
EUROSTER 2006TXRXG
–
INSTALLATION AND OPERATION MANUAL
4
OPENING THE THERMOSTAT
Using a cross-head screwdriver to loosen the housing locking screw. Separate the panel from
the base, while being cautious about the hinges on the right-hand side of the controller.
SELECTION OF THE THERMOSTAT OPERATING MODE
J4
–
selects heating or cooling
mode
Jumper position
J4
COOLING
COOL
J4
HEATING
HEAT
J1
–
selects the temperature
sensor: floor or air.
This function is only active if
jumper J4 is set to heat.
Jumper position
J1
FLOOR
FLOOR
The thermostat is
controlled by a signal from
the floor sensor.
J1
AIR
ROOM
The thermostat is
controlled by a signal from
the air sensor.
INSERTION AND REPLACEMENT OF BATTERIES
Place the batteries in the thermostat while observing the correct polarity. There are installation
markings in the battery compartment. Then install (snap) the thermostat onto the base.
The battery indicator will be visible when the battery voltage reaches the minimum allowable
level. It is recommended to replace the batteries with new alkaline batteries before each
heating season. Reprogram the controller if necessary.
NOTE! Use only alkaline AA batteries to power the thermostat. Do not use
rechargeable batteries because their voltage is lower and their effective time is
shorter.
6.
THERMOSTAT SETTINGS
SETTING THE CLOCK
a)
Turn the knob to the START position.
b)
To change the time, press
.
c)
Press
or
to select the day of the week.
d)
To set the time, press
button again.
e)
Press
or
to set the correct time.