EUROSTER 2006TXRXG Скачать руководство пользователя страница 6

EUROSTER 2006TXRXG 

 INSTALLATION AND OPERATION MANUAL

 

6

 

 

e)

 

IMPORTANT NOTE! Having programmed all 7 days of the week, turn the knob back to 
the start position. The thermostat will automatically start the set program 

RESETTING TO FACTORY SETTINGS 

a)

 

Press  HOLD  and 

 buttons  simultaneously  and  while  holding  them  down  press  the 

RESET button. 

b)

 

Release all buttons. 

c)

 

Press the HOLD button twice and RESET again. 

Factory settings 

Factory programmed temperatures: 
Heating mode 

 

20.4°C 

 

16.2°C

 

Air conditioning mode 

 

22.0°C 

 

25°C

 

Pre-programmed time periods: 
Monday 

 Friday 

 6.00 a.m. to 10.00 p.m. 

 from 10.00 p.m. to 6.00 a.m. 

Saturday 

 Sunday 

 from 6.30 a.m. to 10:30 p.m. 

 from 10.30 p.m. to 6.30 a.m. 

 

SWITCHING OFF THE PROGRAM (WORKING WITH CONSTANT SETTING)/ HOLD 

a)

 

Turn the knob to the START position. 

b)

 

To  switch  off  the  program  and  set  the  operating  temperature  to  a  constant  setting, 

press the HOLD button. The display shows "Temp set" (temperature setting) and "Hold” 

(program switched off). 

c)

 

Use 

 and 

 

buttons to set the desired temperature. 

d)

 

The display will flash for approximately 8 seconds after the selected temperature is set 
and then show the current ambient temperature. The thermostat starts operating in  a 
constant setpoint mode. From this point on, the thermostat maintains a constant user-
set temperature regardless of the programs. 

e)

 

To return to operation with the program press the HOLD button. 

5°C FROST PROTECTION

 

a)

 

Turn the knob to the START position. 

b)

 

Press the HOLD button and hold it for 5 seconds. The letters "A-F" appear on the display. 

c)

 

The  frost  protection  function  has  been  activated.  Regardless  of  the  moment  of  its 
activation, the function is active until 0.00 on Monday. 

d)

 

To switch off the frost protection function and restore the program, press HOLD again. 

TEMPORARY CHANGE OF (MANUAL) TEMPERATURE 

Allows  you  to  change  the  temperature  temporarily  without  modifying  the  stored  programs. 
When  the  comfort  to  economy  temperature  or  vice  versa  is  next  changed,  the  thermostat 
automatically returns to the stored program. 

a)

 

Turn the knob to the START position. 

b)

 

Press 

 or 

 button to call up the current 

 or 

 temperature set point. 

c)

 

Use 

 and 

 buttons to set the desired temperature. 

d)

 

The display will flash for approximately 8 seconds after the selected temperature is set 
and then return to the main display screen. The thermostat will start operation with the 
temporary change of temperature. During the operation with  the temporary change of 
temperature,  in  the  corresponding  period,  the 

 or 

 symbols  disappear  from  the 

main display screen, and 

the “

MANUAL

 inscription appears. 

e)

 

To restore the program, turn the knob in either direction and return to the START position. 

Содержание 2006TXRXG

Страница 1: ...ht temperature Each temperature is modifiable within the range of 5 C 35 C The thermostat is programmable in seven day cycles with an accuracy of 0 5 hour therefore it enables 48 temperature changes in 24 hours It is possible to program different time ranges for each day of the week 2 BASIC FUNCTIONS OF THE THERMOSTAT Does not require leading cable connections between the thermostat and the contro...

Страница 2: ...kdays when programming a thermostat 7 8 Multi purpose setting buttons increase decrease DISPLAY 9 Temporary temperature change MANUAL sign is displayed to indicate that the temperature has been changed manually by means of setting buttons 10 An icon indicating the activation and operation of the controlled device 11 Indication of the current time 12 Current weekday with 1 for Monday and 7 for Sund...

Страница 3: ...d other liquids Do not install any unit showing signs of mechanical damage The thermostat is not a safety component Additional protection devices must be used in systems prone to the risk of damage due to the failure of control systems The device is not intended for use by children Should there be any problem with the proper operation of the thermostat please contact your technician or the manufac...

Страница 4: ...air sensor INSERTION AND REPLACEMENT OF BATTERIES Place the batteries in the thermostat while observing the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base The battery indicator will be visible when the battery voltage reaches the minimum allowable level It is recommended to replace the batteries with new alkaline batteries...

Страница 5: ...ultaneously press and buttons and hold them for 3 seconds c While observing the display use or button to set the desired hysteresis of 0 4 C or 1 C d After five seconds the set point is stored and the device resumes operation CORRECTING THE DISPLAYED TEMPERATURE a Turn the knob to the PN position b Simultaneously press HOLD and buttons and hold them for 3 seconds c While observing the display use ...

Страница 6: ...t on the thermostat maintains a constant user set temperature regardless of the programs e To return to operation with the program press the HOLD button 5 C FROST PROTECTION a Turn the knob to the START position b Press the HOLD button and hold it for 5 seconds The letters A F appear on the display c The frost protection function has been activated Regardless of the moment of its activation the fu...

Страница 7: ... starts flashing in red and green alternately Insert the RX receiver into the mains socket Press the pairing button E on the receiver 3 times the blue LED lights up When the connection is established the blue LED on the receiver goes out If you use only one receiver press the button on the transmitter board the light goes out The pairing mode is ended If you are going to pair multiple receivers ma...

Страница 8: ... Radio signal reception is indicated in green LED flashing three times stands for a very strong range twice for a strong range and once for sufficient range NO RADIO COMMUNICATION If the communication between the thermostat and the receiver is interrupted e g discharged batteries and if this condition lasts for 60 minutes no response from the receiver the receiver switches to the frost protection ...

Страница 9: ...utput cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room In arrangement with a gas boiler 1 Electrical connection block 2 Output cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room MAINTENANCE Do not use solvents and aggressive detergents to clean the thermostat since they may damage the surface of the housing and the d...

Страница 10: ... Hz socket Weight Thermostat without batteries 160 g receiver 340 g Warranty period 2 years Length of the receiver output cable 2 m The operating frequency of the set 868 MHz Maximum power of transmission of the thermostat and receiver 25 mW Thermostat class I Thermostat contribution to the seasonal energy efficiency of room heating 1 12 KIT CONTENTS a Euroster 2006TX thermostat b Euroster RXG rec...

Страница 11: ... persons and nature resulting from the possible presence of hazardous components in the equipment and batteries and inaccurate storage and processing of such equipment and batteries Households play an important role in contributing to reuse and recovery including recycling of waste equipment The attitudes influencing protection of the common good of a clean environment are shaped at this level Hou...

Отзывы: