EUROSTER 2006TXRXG
–
INSTALLATION AND OPERATION MANUAL
6
e)
IMPORTANT NOTE! Having programmed all 7 days of the week, turn the knob back to
the start position. The thermostat will automatically start the set program
RESETTING TO FACTORY SETTINGS
a)
Press HOLD and
buttons simultaneously and while holding them down press the
RESET button.
b)
Release all buttons.
c)
Press the HOLD button twice and RESET again.
Factory settings
Factory programmed temperatures:
Heating mode
20.4°C
16.2°C
Air conditioning mode
22.0°C
25°C
Pre-programmed time periods:
Monday
–
Friday
6.00 a.m. to 10.00 p.m.
from 10.00 p.m. to 6.00 a.m.
Saturday
–
Sunday
from 6.30 a.m. to 10:30 p.m.
from 10.30 p.m. to 6.30 a.m.
SWITCHING OFF THE PROGRAM (WORKING WITH CONSTANT SETTING)/ HOLD
a)
Turn the knob to the START position.
b)
To switch off the program and set the operating temperature to a constant setting,
press the HOLD button. The display shows "Temp set" (temperature setting) and "Hold”
(program switched off).
c)
Use
and
buttons to set the desired temperature.
d)
The display will flash for approximately 8 seconds after the selected temperature is set
and then show the current ambient temperature. The thermostat starts operating in a
constant setpoint mode. From this point on, the thermostat maintains a constant user-
set temperature regardless of the programs.
e)
To return to operation with the program press the HOLD button.
5°C FROST PROTECTION
a)
Turn the knob to the START position.
b)
Press the HOLD button and hold it for 5 seconds. The letters "A-F" appear on the display.
c)
The frost protection function has been activated. Regardless of the moment of its
activation, the function is active until 0.00 on Monday.
d)
To switch off the frost protection function and restore the program, press HOLD again.
TEMPORARY CHANGE OF (MANUAL) TEMPERATURE
Allows you to change the temperature temporarily without modifying the stored programs.
When the comfort to economy temperature or vice versa is next changed, the thermostat
automatically returns to the stored program.
a)
Turn the knob to the START position.
b)
Press
or
button to call up the current
or
temperature set point.
c)
Use
and
buttons to set the desired temperature.
d)
The display will flash for approximately 8 seconds after the selected temperature is set
and then return to the main display screen. The thermostat will start operation with the
temporary change of temperature. During the operation with the temporary change of
temperature, in the corresponding period, the
or
symbols disappear from the
main display screen, and
the “
MANUAL
”
inscription appears.
e)
To restore the program, turn the knob in either direction and return to the START position.