7

 

 

CONNECTING FLOOR SENSOR 

a)

 

Check if the J1 jumper is in the floor position (point 4.4.) 

b)

 

Connect the floor sensor to terminals 4 and 5 of the thermostat. 

c)

 

Reset the thermostat. 

d)

 

The  thermostat  operates  according  to  the  floor  sensor  temperature  read-out.  The 

temperature  control  range  increases  to  45°C.  The  standard  temperature  sensor  is 

inactive. 

7.

 

RXG RECEIVER SETTINGS 

ESTABLISHING  CONNECTION  BETWEEN  2006TX  THERMOSTAT  AND  RXG  RECEIVER 
OR RECEIVERS (PAIRING) 

Each thermostat and each receiver has a unique number that distinguishes it from others. It is 
not  possible  for  any  thermostat  not  paired  with  the  particular  receiver  to  interfere  with  the 
operation of another pair or set. 
The  thermostat  may  be  paired  with  other  receivers  at  any  time.  A  blackout,  battery 
replacement as well as a complete reset of all thermostat settings do not affect the pairing of 
devices in any way. 

Pairing procedure: 

 

Press the RESET button on the thermostat (under the front flap) 

 

Remove the thermostat cover 

 

Press  the  button  on  the  transmitter  board  three  times,  the  LED  starts  flashing  in  red 
and green alternately  

 

 

Insert the RX receiver into the mains socket 

 

Press the pairing button (E) on the receiver 3 times 

 the blue LED lights up 

 

When the connection is established, the blue LED on the receiver goes out 

 

If you use only one receiver, press the button on the transmitter board, the light goes 
out. The pairing mode is ended. 

If you are going to pair multiple receivers (maximum 6), proceed as follows: 

 

When the first receiver is detected 

 

Insert the second receiver into a mains socket 

 

Press the button on the receiver 3 times 

 the blue LED lights up 

 

When the receiver is detected, the blue led goes out 

 

Proceed  similarly  with  the  connection  of  the  subsequent  receivers,  then  press  the 
button on the transmitter board. The pairing mode is ended. 

Caution! Pairing mode is only available for 10 minutes after connecting the receiver 
to  the  mains  and  resetting  or  installing  batteries  in  the  thermostat! 
Factory-established  thermostat

receiver  pairs  are  paired,  however,  pairing  may  be 

repeated if necessary. 

SELECTING OPERATING MODE 

Press  and  hold  the  pairing  button  (E)  on  the  receiver  for  approximately  5  seconds. 
Depending on the mode set, the green or red LED lights up. Each time the button is pressed, 
the operating mode changes. When you select the mode, the receiver restores operation. 

Содержание 2006TXRXG

Страница 1: ...ht temperature Each temperature is modifiable within the range of 5 C 35 C The thermostat is programmable in seven day cycles with an accuracy of 0 5 hour therefore it enables 48 temperature changes in 24 hours It is possible to program different time ranges for each day of the week 2 BASIC FUNCTIONS OF THE THERMOSTAT Does not require leading cable connections between the thermostat and the contro...

Страница 2: ...kdays when programming a thermostat 7 8 Multi purpose setting buttons increase decrease DISPLAY 9 Temporary temperature change MANUAL sign is displayed to indicate that the temperature has been changed manually by means of setting buttons 10 An icon indicating the activation and operation of the controlled device 11 Indication of the current time 12 Current weekday with 1 for Monday and 7 for Sund...

Страница 3: ...d other liquids Do not install any unit showing signs of mechanical damage The thermostat is not a safety component Additional protection devices must be used in systems prone to the risk of damage due to the failure of control systems The device is not intended for use by children Should there be any problem with the proper operation of the thermostat please contact your technician or the manufac...

Страница 4: ...air sensor INSERTION AND REPLACEMENT OF BATTERIES Place the batteries in the thermostat while observing the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base The battery indicator will be visible when the battery voltage reaches the minimum allowable level It is recommended to replace the batteries with new alkaline batteries...

Страница 5: ...ultaneously press and buttons and hold them for 3 seconds c While observing the display use or button to set the desired hysteresis of 0 4 C or 1 C d After five seconds the set point is stored and the device resumes operation CORRECTING THE DISPLAYED TEMPERATURE a Turn the knob to the PN position b Simultaneously press HOLD and buttons and hold them for 3 seconds c While observing the display use ...

Страница 6: ...t on the thermostat maintains a constant user set temperature regardless of the programs e To return to operation with the program press the HOLD button 5 C FROST PROTECTION a Turn the knob to the START position b Press the HOLD button and hold it for 5 seconds The letters A F appear on the display c The frost protection function has been activated Regardless of the moment of its activation the fu...

Страница 7: ... starts flashing in red and green alternately Insert the RX receiver into the mains socket Press the pairing button E on the receiver 3 times the blue LED lights up When the connection is established the blue LED on the receiver goes out If you use only one receiver press the button on the transmitter board the light goes out The pairing mode is ended If you are going to pair multiple receivers ma...

Страница 8: ... Radio signal reception is indicated in green LED flashing three times stands for a very strong range twice for a strong range and once for sufficient range NO RADIO COMMUNICATION If the communication between the thermostat and the receiver is interrupted e g discharged batteries and if this condition lasts for 60 minutes no response from the receiver the receiver switches to the frost protection ...

Страница 9: ...utput cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room In arrangement with a gas boiler 1 Electrical connection block 2 Output cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room MAINTENANCE Do not use solvents and aggressive detergents to clean the thermostat since they may damage the surface of the housing and the d...

Страница 10: ... Hz socket Weight Thermostat without batteries 160 g receiver 340 g Warranty period 2 years Length of the receiver output cable 2 m The operating frequency of the set 868 MHz Maximum power of transmission of the thermostat and receiver 25 mW Thermostat class I Thermostat contribution to the seasonal energy efficiency of room heating 1 12 KIT CONTENTS a Euroster 2006TX thermostat b Euroster RXG rec...

Страница 11: ... persons and nature resulting from the possible presence of hazardous components in the equipment and batteries and inaccurate storage and processing of such equipment and batteries Households play an important role in contributing to reuse and recovery including recycling of waste equipment The attitudes influencing protection of the common good of a clean environment are shaped at this level Hou...

Отзывы: