EUROSTER 2006TXRXG Скачать руководство пользователя страница 10

EUROSTER 2006TXRXG 

 INSTALLATION AND OPERATION MANUAL

 

10

 

 

11.

 

TECHNICAL DATA 

Controlled device 

heating/air conditioning systems 

Supply voltage 

3 V  (2  pieces  of  alkaline  AA  batteries) 
receiver 

 230 V 50 Hz 

Thermostat output 

relay, voltage-free type, SPST 

Maximum load 

5 A 230 V 50 Hz 

Temperature measurement range 

°C...+50

 

°C

 

Temperature adjustment range 

+5 

°C...+35

 

°C 

 

°C to +45

 

°C in floor sensor mode

 

Temperature adjustment accuracy 

0.2 

°C

 

Temperature reading accuracy 

0.1 

°C

 

Hysteresis range 

0.4 

°C or 1

 

°C 

 

Visual signalization 

backlit LCD 

Operation temperature 

+5 

°C...+40

 

°C

 

Storage temperature 

-10 

°C...+45

 

°C

 

Ingress protection rating 

IP 20 

Color 

white 

Mounting method 

thermostat 

 stand 

receiver 

 230 V 50 Hz socket 

Weight 

Thermostat without batteries 

 160 g 

receiver 

 340 g 

Warranty period 

2 years 

Length of the receiver output cable 

2 m 

The operating frequency of the set 

868 MHz 

Maximum  power  of  transmission  of  the 
thermostat and receiver 

< 25 mW 

Thermostat class: 

I  

Thermostat  contribution  to  the  seasonal 
energy efficiency of room heating 
 

1 % 

12.

 

KIT CONTENTS 

a)

 

Euroster 2006TX thermostat 

b)

 

Euroster RXG receiver 

c)

 

2 pieces of alkaline AA batteries 

d)

 

thermostat stand 

e)

 

Installation and Operation Manual with Warranty Certificate 

SIMPLIFIED DECLARATION OF CONFORMITY 

P.H.P.U. AS AGNIESZKA 

SZYMAŃSKA

-

KACZYŃSKA hereby declares that the type of EUROSTER 

2006TXRXG  equipment  conforms  to  the  following  directives:  2014/35/EU  (LVD),  2014/30/EU 
(EMC), 2014/53/EU (RED), 2011/65/EU (RoHS). 
The  complete  text  of  the  Declaration  of  EU  conformity  is  available  at  the  following  Internet 
address:  www.euroster.pl 

 

 

Содержание 2006TXRXG

Страница 1: ...ht temperature Each temperature is modifiable within the range of 5 C 35 C The thermostat is programmable in seven day cycles with an accuracy of 0 5 hour therefore it enables 48 temperature changes in 24 hours It is possible to program different time ranges for each day of the week 2 BASIC FUNCTIONS OF THE THERMOSTAT Does not require leading cable connections between the thermostat and the contro...

Страница 2: ...kdays when programming a thermostat 7 8 Multi purpose setting buttons increase decrease DISPLAY 9 Temporary temperature change MANUAL sign is displayed to indicate that the temperature has been changed manually by means of setting buttons 10 An icon indicating the activation and operation of the controlled device 11 Indication of the current time 12 Current weekday with 1 for Monday and 7 for Sund...

Страница 3: ...d other liquids Do not install any unit showing signs of mechanical damage The thermostat is not a safety component Additional protection devices must be used in systems prone to the risk of damage due to the failure of control systems The device is not intended for use by children Should there be any problem with the proper operation of the thermostat please contact your technician or the manufac...

Страница 4: ...air sensor INSERTION AND REPLACEMENT OF BATTERIES Place the batteries in the thermostat while observing the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base The battery indicator will be visible when the battery voltage reaches the minimum allowable level It is recommended to replace the batteries with new alkaline batteries...

Страница 5: ...ultaneously press and buttons and hold them for 3 seconds c While observing the display use or button to set the desired hysteresis of 0 4 C or 1 C d After five seconds the set point is stored and the device resumes operation CORRECTING THE DISPLAYED TEMPERATURE a Turn the knob to the PN position b Simultaneously press HOLD and buttons and hold them for 3 seconds c While observing the display use ...

Страница 6: ...t on the thermostat maintains a constant user set temperature regardless of the programs e To return to operation with the program press the HOLD button 5 C FROST PROTECTION a Turn the knob to the START position b Press the HOLD button and hold it for 5 seconds The letters A F appear on the display c The frost protection function has been activated Regardless of the moment of its activation the fu...

Страница 7: ... starts flashing in red and green alternately Insert the RX receiver into the mains socket Press the pairing button E on the receiver 3 times the blue LED lights up When the connection is established the blue LED on the receiver goes out If you use only one receiver press the button on the transmitter board the light goes out The pairing mode is ended If you are going to pair multiple receivers ma...

Страница 8: ... Radio signal reception is indicated in green LED flashing three times stands for a very strong range twice for a strong range and once for sufficient range NO RADIO COMMUNICATION If the communication between the thermostat and the receiver is interrupted e g discharged batteries and if this condition lasts for 60 minutes no response from the receiver the receiver switches to the frost protection ...

Страница 9: ...utput cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room In arrangement with a gas boiler 1 Electrical connection block 2 Output cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room MAINTENANCE Do not use solvents and aggressive detergents to clean the thermostat since they may damage the surface of the housing and the d...

Страница 10: ... Hz socket Weight Thermostat without batteries 160 g receiver 340 g Warranty period 2 years Length of the receiver output cable 2 m The operating frequency of the set 868 MHz Maximum power of transmission of the thermostat and receiver 25 mW Thermostat class I Thermostat contribution to the seasonal energy efficiency of room heating 1 12 KIT CONTENTS a Euroster 2006TX thermostat b Euroster RXG rec...

Страница 11: ... persons and nature resulting from the possible presence of hazardous components in the equipment and batteries and inaccurate storage and processing of such equipment and batteries Households play an important role in contributing to reuse and recovery including recycling of waste equipment The attitudes influencing protection of the common good of a clean environment are shaped at this level Hou...

Отзывы: