SigNET 200/300 User Guide  

 6  

 

  ELAB 1543 

3.  Setting, Unsetting, and Restoring the System 

The following functions are available to users by entering a user code; these 
functions do not require menu navigation on the Keypad. User codes 
comprise 4, 5, or 6 digits, depending upon the programming grade of the 
system.  
A user’s permission rights, i.e. ability to see menus and options available on 
the SigNET 200/300 system, are programmed by the installation engineer. If 
users cannot see options described in this manual, they do not have rights to 
access such functionality. 

When a code is entered, the digits display as asterixes and the left function 
key displays the QUIT option. This is for security reasons, so codes are not 
visible when entered. 

After entering a code, the following options are presented: FULLSET, 
PARTSET A, PARTSET B, MENUS. Scroll these options by using the 
up/down arrow keys. An ellipsis (…) on accompanying graphics denotes 
when there is a choice of menu selection by scrolling. 

3.1 

Setting the System: FULLSET 

The FULLSET option provides the following functionality: 

  Full protection to a building (opening of alarm zones activates alarm) 

  Opening of entry/exit zones starts the entry timer. If the alarm is not 

unset before the entry timer expires, the alarm is activated 

To select the FULLSET option, enter a valid user code, and press SELECT 
(right soft key). The second line displays the exit time and the buzzer sounds 
to indicate that the user should exit the building. When the system has been 
fully set, the LCD displays FULLSET on the bottom line for approximately 10 
seconds. 

If the alarm fails to set, see Section 3.4, Failing to Set the System. 

3.2 

Setting the System: PARTSET A 

The PARTSET A option provides the following functionality: 

  Perimeter protection to a building while allowing free movement 

through the exit and access areas 

  Exclusion of EXCLUDE A zones from protection 

  Instant activation of alarm on selection of mode; by default there are 

no exit times associated with PARTSET A 

To select PARTSET A, enter a valid user code, scroll to the PARTSET A 
option and press SELECT (right soft key).  

If the alarm fails to set, see Section 3.4, Failing to Set the System. 

3.3 

Setting the System: PARTSET B 

The PARTSET B option provides the following functionality: 

  Perimeter protection to a building while allowing free movement 

through the exit and access areas 

  Exclusion of EXCLUDE B zones from protection 

  Instant activation of alarm on selection of mode; by default there are 

no exit times associated with PARTSET B 

To select PARTSET B, enter a valid user code, scroll to the PARTSET B 
option and press SELECT (right soft key). 

 

Note 

Partset A and Partset B configuration modes are dependent upon how the system has been 
programmed. 

…FULLSET?... 
EXIT  

 

SELECT 

…PARTSET A?... 
EXIT  

 

SELECT 

…PARTSET B?... 
EXIT  

 

SELECT 

…MENUS… 
EXIT  

 

SELECT 

…FULLSET?... 
EXIT  

 

SELECT 

18/04/2008 12:30 
SETTING 45 SECONDS 

18/04/2008 12:30 
SYSTEM FULLSET 

…PARTSET A?... 
EXIT  

 

SELECT 

18/04/2008 12:54 
PARTSET A SET   

…PARTSET B?... 
EXIT  

 

SELECT 

18/04/2008 12:55 
PARTSET B SET   

Содержание SigNET200 Series

Страница 1: ...E L A B1 5 4 3 S i g N E T2 0 0 3 0 0S e r i e s U s e r G u i d e...

Страница 2: ...en changing or installing expanders on the SigNET 200 300 system always ensure that all anti static precautions are adhered to while handling connectors wires terminals and PCBs Europlex Technologies...

Страница 3: ...THE SYSTEM 7 3 7 RESTORING AN ALARM ACTIVATION ALERT 7 3 8 CODED RESTORE 8 3 9 USING 868MHZ WIRELESS FOB 8 3 10 USING A PORTABLE ACE 8 3 11 USING X10 FEATURES 9 4 USER MENU OPTIONS 10 4 1 INHIBITING A...

Страница 4: ...NET Keypad may be factory fitted with a Portable ACE PACE proximity device reader and or a wireless module for the enrolment of wireless sensors Figure 1 SigNET Keypad Table 1 LED Status Indicators LE...

Страница 5: ...e down arrow key moves the user to the next programming option in the same menu level Continually press this key to scroll through all programming options available on the current menu level In alphan...

Страница 6: ...buzzer sounds to indicate that the user should exit the building When the system has been fully set the LCD displays FULLSET on the bottom line for approximately 10 seconds If the alarm fails to set...

Страница 7: ...on the Keypad and the Alert LED flashes The Keypad continues to display the alert until the alert is restored 3 7 Restoring an Alarm Activation Alert Alert conditions on the SigNET are indicated on t...

Страница 8: ...digit reset code displays on the top line 4 Provide 6 digit code to installer ARC 5 Receive newly generated code from installer ARC 6 Enter new code at the AUTH CODE prompt 7 Press SELECT The message...

Страница 9: ...a hall light could be configured to turn on when the front door of the house is opened Alternatively the function can be controlled directly at the Keypad X10 settings are programmed by the installati...

Страница 10: ...l to the ISOLATE option and press SELECT right soft key 2 Scroll to the ZONES option and press SELECT right soft key 3 A list of zones on the system displays Select the required zone and toggle the se...

Страница 11: ...Chime Function The chime function can be enabled or disabled on all zones where the chime has been programmed as an audible alert feature To enable or disable the chime function 1 Scroll to the CHIME...

Страница 12: ...ts can be sent to users as SMS messages Alarm Activation Confirmed Alarms Fault and Tamper Arming and Disarming Mode Change Inhibit and Isolate All other types of events 4 9 1 SMS Events To receive Ev...

Страница 13: ...Depending on the SMS authentication configured by the installation engineer the user s mode of SMS may vary If the system SMS Authentication is set to the SMS PIN Code or Caller ID it is necessary to...

Страница 14: ...code followed by either a space or a full stop Where is the code and command is the command command or command For example the command HELP is this text HELP or HELP Table 3 COMMANDS code Using Code U...

Страница 15: ...engineer access 1 Scroll to the GRANT ACCESS option and press SELECT right soft key 2 Select the ALLOW ENGINEER option right soft key and select ENABLED To disallow engineer manufacturer access follo...

Страница 16: ...this mode An exit timer can be applied to this mode by enabling the Partset A timed variable To perform a PARTSET A see Section 3 2 PARTSET B Standard Manager The PARTSET B option applies protection t...

Страница 17: ...e time and date information is accurate these fields are presented in the event log when reporting system events To set date or time see Section 4 3 TEST Standard Manager This menu option provides the...

Страница 18: ...SigNET 200 300 User Guide 18 ELAB 1543 Appendix C Zone Chart Zone Description...

Отзывы: