SigNET 200/300 User Guide  

 

 
E-LAB-1543  

3.4 

Failing to Set the System 

If the message FAILED TO SET is displayed on the Keypad, it means an open 
or fault condition was detected on an alarm zone when the FULLSET or 
PARTSET A/B option was selected. The Keypad also displays the zone number 
and description.  

To set the system, locate the zone and close or fix the fault. Repeat the 
FULLSET or PARTSET A/B operation.  

3.5 

Force Setting the System 

The system can be forced to set while an alarm zone is still open. This operation 
inhibits the open zone and sets the system as normal. 

If a user has the right to FORCE SET the system and an alarm zone is open, 
when the FULLSET or PARTSET option is selected, the Keypad buzzer beeps 
and the first line of the display indicates the open zone. The user is presented 
with the options to QUIT (left soft key) or FORCE (right soft key).  

QUIT: Selecting this option aborts the attempt to set the system and returns the 
user to User Programming 

FORCE: Selecting this option inhibits the open zone and forces the system to set 

3.6 

Unsetting the System 

To UNSET a system: 
1.  Enter a valid user code. The Keypad displays a prompt to unset the 

system.  

2.  To UNSET the system, press SELECT (right soft key). The Keypad 

display indicates that the system is unset on the bottom line of the 
display for approximately 5 seconds. After this time has elapsed, the 
bottom line is cleared.  

3.  If the alarm has been activated, entering the user code silences all bells 

and strobes and the message PANEL DISARMED is displayed on the 
Keypad for approximately 5 seconds.  

4.  The source of the alarm condition is displayed on the Keypad and the 

Alert LED flashes. The Keypad continues to display the alert until the 
alert is restored.  

3.7 

Restoring an Alarm Activation (Alert) 

Alarm conditions on the SigNET 200/300 are indicated on the Keypad by a 
flashing yellow Alert LED (see Section 2, Using the Keypad) and by activation of 
the buzzer. The Keypad displays the location and nature of the alert condition. 

To restore an alert condition triggered by a zone opening: 
1.  Locate the open zone (displayed on the Keypad) and restore the alarm 

sensor to its normal state by closing the door or window. 

2.  Enter a valid user code and select the RESTORE option (right soft key). 

The zone that caused the alert is displayed on the top line of the display.  

3.  Press the right menu key to restore the alert. The message ALL ALERTS 

RESTORED is displayed and the flashing Alert LED is turned off.  

For system or communications type alert conditions (Mains failure or E-BUS 
disconnect), locate the source of the alert condition and check that all wires and 
cables are properly connected.  

For a tamper alert, ensure the lids on all enclosures and devices are correctly 
closed. If the physical fault cannot be restored to its normal operating state, 
contact the installation engineer. The alarm system can still be operated by either 
inhibiting or isolating the fault condition.  

 

 

ZONE X OPEN 

QUIT     FORCE 

 

FORCED SET? 

BACK         SELECT 

FAILED TO SET 

 

ZONE 3 
KITCHEN 

 

 

UNSET? 

EXIT              SELECT 

01 SEP 06 17:00  
 UNSET 

 

PANEL DISARMED 

 

ALARM ZONE 2 
FIRST ZONE 

 

ALARM ZONE 2 
Sitting Room 

RESTORE 
EXIT        SELECT 

Sitting Room 
QUIT       RESTORE 

ALL ALERTS 
RESTORED 

Содержание SigNET 200

Страница 1: ...SigNET 200 300 User Guide E LAB 1543 1 SigNET 200 300 User Guide...

Страница 2: ...7 When changing or installing expanders on the SigNET 200 300 system always ensure that all anti static precautions are adhered to while handling connectors wires terminals and PCBs Europlex Technolog...

Страница 3: ...ORCE SETTING THE SYSTEM 7 3 6 UNSETTING THE SYSTEM 7 3 7 RESTORING AN ALARM ACTIVATION ALERT 7 3 8 USING X10 FEATURES 8 4 USER MENU OPTIONS 8 4 1 ISOLATING A ZONE OR FAULT 8 4 2 INHIBITING A ZONE 9 4...

Страница 4: ...SigNET Keypad may be factory fitted with a Portable ACE PACE proximity device reader and or a wireless module for the enrolment of wireless sensors Figure 1 SigNET Keypad Table 1 LED Status Indicators...

Страница 5: ...advances the user through the menus in the same way as pressing the SELECT option right soft key When no more menu options can be selected this key has no function In data entry mode press this key to...

Страница 6: ...user should exit the building When the system has been fully set the LCD displays FULLSET on the bottom line for approximately 10 seconds If the alarm fails to set see Section 3 4 Failing to Set the S...

Страница 7: ...age PANEL DISARMED is displayed on the Keypad for approximately 5 seconds 4 The source of the alarm condition is displayed on the Keypad and the Alert LED flashes The Keypad continues to display the a...

Страница 8: ...ilable to users through the navigational menus on the Keypad In navigation mode the user selects one of a number of pre defined programming options from a list Pressing the up down arrow keys scrolls...

Страница 9: ...e with fewer numbers than it is set to receive To change a user code 1 Enter the current user code 2 Using the up down arrow keys scroll to the MENUS option and press SELECT right soft key 3 Scroll to...

Страница 10: ...he left and right arrow keys Press ENTER right soft key to save the new date If an attempt is made to save an invalid date value the text INVALID VALUE is displayed for 1 second and the user is prompt...

Страница 11: ...system on the bottom line and all previous events are displayed for 1 second in turn 5 To view an event from a particular date enter the date with the numeric keys 4 8 Enabling the Chime Function The...

Страница 12: ...se profiles are defaults and can be changed 7 Enter the user code that will be assigned to the new user and press SELECT right soft key 8 The Keypad confirms that the new user has been created Editing...

Страница 13: ...of this mode An exit timer can be applied to this mode by enabling the Partset A timed variable To perform a PARTSET A see Section 3 2 PARTSET B Standard Master The PARTSET B option applies protection...

Страница 14: ...event log when reporting system events To set the date and time see Section 4 5 TEST Standard Master This menu option provides the following test features 1 Bell test The bell test activates the exte...

Страница 15: ...SigNET 200 300 User Guide E LAB 1543 15 Zone Chart Zone Description...

Отзывы: