SigNET 200/300 User Guide  

E-LAB-1543  

 

11 

6.  When WALK TEST is selected, users can test the operation of each alarm device by activating the device 

and checking to hear if an audible beep sounds at the Keypad.  

4.7 

Viewing the Event Log 

The most recent events on the system can be viewed by selecting the EVENT 
LOG option. The most recent events are displayed on the bottom line of the 
display and all previous events are displayed for 1 second in turn.  

To view the event log on the Keypad: 
1.  Enter a valid user code. 
2.  Using the up/down arrow keys, scroll down to the MENUS option and 

press SELECT (right soft key). 

3.  Scroll down to the EVENT LOG option and press SELECT (right soft 

key).  

4.  The Keypad displays the most recent event logged on the system on 

the bottom line, and all previous events are displayed for 1 second in 
turn. 

5.  To view an event from a particular date, enter the date with the numeric 

keys. 

4.8 

Enabling the Chime Function 

The chime function can be enabled or disabled on all zones where the chime 
has been programmed as an audible alert feature.  

To enable or disable the chime function:  
1.  Enter a valid user code.  
2.  Using the up/down arrow keys, scroll down to the MENUS option and 

press SELECT (right soft key). 

3.  Scroll to the CHIME option and press SELECT (right soft key). 
4.  Choose to enable or disable the chime function by toggling between the 

two options.  

 

4.9 Using 

SMS 

For instructions on using the SMS feature, visit the Downloads section of Europlex’s web site at 

www.europlex-

signet.com/downloads

 and download the SMS User Guide. 

 
 

 

EVENT LOG 

EXIT               SELECT 

 

01 SEP 06 17:00 

INHIBIT: ZONE 3 

 

 

MENUS 

EXIT              SELECT 

 

MENUS 

EXIT              SELECT 

 

CHIME 

EXIT              SELECT 

 

ENABLED 

EXIT              SELECT 

Содержание SigNET 200

Страница 1: ...SigNET 200 300 User Guide E LAB 1543 1 SigNET 200 300 User Guide...

Страница 2: ...7 When changing or installing expanders on the SigNET 200 300 system always ensure that all anti static precautions are adhered to while handling connectors wires terminals and PCBs Europlex Technolog...

Страница 3: ...ORCE SETTING THE SYSTEM 7 3 6 UNSETTING THE SYSTEM 7 3 7 RESTORING AN ALARM ACTIVATION ALERT 7 3 8 USING X10 FEATURES 8 4 USER MENU OPTIONS 8 4 1 ISOLATING A ZONE OR FAULT 8 4 2 INHIBITING A ZONE 9 4...

Страница 4: ...SigNET Keypad may be factory fitted with a Portable ACE PACE proximity device reader and or a wireless module for the enrolment of wireless sensors Figure 1 SigNET Keypad Table 1 LED Status Indicators...

Страница 5: ...advances the user through the menus in the same way as pressing the SELECT option right soft key When no more menu options can be selected this key has no function In data entry mode press this key to...

Страница 6: ...user should exit the building When the system has been fully set the LCD displays FULLSET on the bottom line for approximately 10 seconds If the alarm fails to set see Section 3 4 Failing to Set the S...

Страница 7: ...age PANEL DISARMED is displayed on the Keypad for approximately 5 seconds 4 The source of the alarm condition is displayed on the Keypad and the Alert LED flashes The Keypad continues to display the a...

Страница 8: ...ilable to users through the navigational menus on the Keypad In navigation mode the user selects one of a number of pre defined programming options from a list Pressing the up down arrow keys scrolls...

Страница 9: ...e with fewer numbers than it is set to receive To change a user code 1 Enter the current user code 2 Using the up down arrow keys scroll to the MENUS option and press SELECT right soft key 3 Scroll to...

Страница 10: ...he left and right arrow keys Press ENTER right soft key to save the new date If an attempt is made to save an invalid date value the text INVALID VALUE is displayed for 1 second and the user is prompt...

Страница 11: ...system on the bottom line and all previous events are displayed for 1 second in turn 5 To view an event from a particular date enter the date with the numeric keys 4 8 Enabling the Chime Function The...

Страница 12: ...se profiles are defaults and can be changed 7 Enter the user code that will be assigned to the new user and press SELECT right soft key 8 The Keypad confirms that the new user has been created Editing...

Страница 13: ...of this mode An exit timer can be applied to this mode by enabling the Partset A timed variable To perform a PARTSET A see Section 3 2 PARTSET B Standard Master The PARTSET B option applies protection...

Страница 14: ...event log when reporting system events To set the date and time see Section 4 5 TEST Standard Master This menu option provides the following test features 1 Bell test The bell test activates the exte...

Страница 15: ...SigNET 200 300 User Guide E LAB 1543 15 Zone Chart Zone Description...

Отзывы: