SigNET 200/300 User Guide  
 

 
4  

 

E-LAB-1543 

1.  Introducing the SigNET 200/300 System 

The SigNET 200/300 system must be installed by a qualified installation engineer. When the installation has been 
completed, the engineer provides users with passwords to set or unset and configure the system as required.  

2. Using the Keypad 

The SigNET Keypad is a wall-mounted programming interface unit that allows users to enter User Programming 
menus (password protected), and to perform operational procedures (arm/disarm) on the system. The Keypad unit 
includes an integral front tamper switch and has a 2 line x 16 character display. Three LEDs provide information on 
AC power, system alerts, and communications status. The Keypad features an easy-to-use navigation key to assist 
in locating required programming options, and has 2 context sensitive soft keys (left and right) for selecting the 
required menu or program setting. 

The SigNET Keypad may be factory fitted with a Portable ACE (PACE) proximity device reader and/or a wireless 
module for the enrolment of wireless sensors.  

Figure 1 – SigNET Keypad 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Table 1 – LED Status Indicators 

LED  

Description 

AC Mains LED 
(green)

 

Indicates presence or failure of the Mains supply 

FLASHING:

 AC Mains fault detected 

STEADY:

 AC Mains OK

 

System Alert  
(yellow)

 

Indicates a system alert 

FLASHING:

 System Alert detected; display indicates the location and nature of the alert. If the 

system is SET, no indication  of system alerts is given. 

OFF:

 No alert detected 

Comms LED 
(red)

 

Indicates status of the E-BUS communications when in FULL ENGINEER programming 

Programming Keys 

1 x multi-functional navigation key 
2 x context sensitive programming 
keys (left and right)  

01 Dec 06 17:00 

AC Mains LED 

System Alert LED 

Comms LED 

Keypad 

12 x alphanumeric 
keys for numeric 
and text data entry

Portable ACE 
Receiver Area 

Licence 
Details 

Installer Contact 

Installer Name 

Installation Date 

Pull-down Information Tab 

The installer contact and licence 
details are located on the pull 
down information tab at the rear 
of the unit 

Содержание SigNET 200

Страница 1: ...SigNET 200 300 User Guide E LAB 1543 1 SigNET 200 300 User Guide...

Страница 2: ...7 When changing or installing expanders on the SigNET 200 300 system always ensure that all anti static precautions are adhered to while handling connectors wires terminals and PCBs Europlex Technolog...

Страница 3: ...ORCE SETTING THE SYSTEM 7 3 6 UNSETTING THE SYSTEM 7 3 7 RESTORING AN ALARM ACTIVATION ALERT 7 3 8 USING X10 FEATURES 8 4 USER MENU OPTIONS 8 4 1 ISOLATING A ZONE OR FAULT 8 4 2 INHIBITING A ZONE 9 4...

Страница 4: ...SigNET Keypad may be factory fitted with a Portable ACE PACE proximity device reader and or a wireless module for the enrolment of wireless sensors Figure 1 SigNET Keypad Table 1 LED Status Indicators...

Страница 5: ...advances the user through the menus in the same way as pressing the SELECT option right soft key When no more menu options can be selected this key has no function In data entry mode press this key to...

Страница 6: ...user should exit the building When the system has been fully set the LCD displays FULLSET on the bottom line for approximately 10 seconds If the alarm fails to set see Section 3 4 Failing to Set the S...

Страница 7: ...age PANEL DISARMED is displayed on the Keypad for approximately 5 seconds 4 The source of the alarm condition is displayed on the Keypad and the Alert LED flashes The Keypad continues to display the a...

Страница 8: ...ilable to users through the navigational menus on the Keypad In navigation mode the user selects one of a number of pre defined programming options from a list Pressing the up down arrow keys scrolls...

Страница 9: ...e with fewer numbers than it is set to receive To change a user code 1 Enter the current user code 2 Using the up down arrow keys scroll to the MENUS option and press SELECT right soft key 3 Scroll to...

Страница 10: ...he left and right arrow keys Press ENTER right soft key to save the new date If an attempt is made to save an invalid date value the text INVALID VALUE is displayed for 1 second and the user is prompt...

Страница 11: ...system on the bottom line and all previous events are displayed for 1 second in turn 5 To view an event from a particular date enter the date with the numeric keys 4 8 Enabling the Chime Function The...

Страница 12: ...se profiles are defaults and can be changed 7 Enter the user code that will be assigned to the new user and press SELECT right soft key 8 The Keypad confirms that the new user has been created Editing...

Страница 13: ...of this mode An exit timer can be applied to this mode by enabling the Partset A timed variable To perform a PARTSET A see Section 3 2 PARTSET B Standard Master The PARTSET B option applies protection...

Страница 14: ...event log when reporting system events To set the date and time see Section 4 5 TEST Standard Master This menu option provides the following test features 1 Bell test The bell test activates the exte...

Страница 15: ...SigNET 200 300 User Guide E LAB 1543 15 Zone Chart Zone Description...

Отзывы: