Appendix B: Standard User Settings 

The operational features of the SigNET 200/300 system are described below. The installation engineer will inform 
users of their user rights assigned to each user profile. Depending on how the system has been programmed, users 
may have rights to all or some of these features.  

 

Operation 

User Profile 
Default 

Description 

FULLSET 

 

Limited 
Standard  
Master 

The FULLSET operation fully sets the alarm system and provides full 
protection to a building (opening of any alarm zones activates the alarm).  
On selecting FULLSET, the buzzer sounds and the Keypad display 
counts down the exit time period. Exit the building before this time period 
has expired.  
When the exit time period has expired, the system is set and opening of 
entry/exit zones starts the entry timer. If the system is not Unset before 
the entry timer expires, the alarm is activated. 
To perform a FULLSET, see Section 3.1. 

PARTSET A 
 

 

Standard  
Master 

The PARTSET A option provides perimeter protection to a building while 
allowing free movement through the exit and access areas.  
Zones that have been classified as 

EXCLUDE A

 remain unprotected in 

this mode. By default, there is no exit time; the system sets instantly on 
selection of this mode. An exit timer can be applied to this mode by 
enabling the Partset A timed variable. 
To perform a PARTSET A, see Section 3.2. 

PARTSET B 
 

 

Standard  
Master 

The PARTSET B option applies protection to all zones except those that 
have been classified as 

EXCLUDE B

By default there is no exit time; the system sets instantly on selection of 
this mode. An exit timer can be applied to this mode by enabling the 
Partset B timed variable. 
To perform a PARTSET B, see Section 3.3. 

FORCESET 

 

Standard  
Master 

The FORCESET option is presented on the Keypad display when an 
attempt is made to set the system while an alarm zone is faulty or still 
open (the top line of the display shows the open zone).  
Selecting this option sets the alarm and inhibits the zone for that set 
period.  
To perform a FORCESET, see Section 3.5. 

UNSET 

 

Limited 
Standard  
Master 

The UNSET operation unsets the alarm. This menu option is only 
presented on the Keypad after an alarm has been activated and a valid 
user code has been entered. 
To UNSET the system, see Section 3.6.  

RESTORE 

 

Standard  
Master 

The RESTORE operation restores an alert condition on the system and 
clears the alert message associated with that alert condition.  
An alert condition can only be restored after the zone(s) or fault(s) that 
triggered the alert condition have been restored to their normal operating 
state and the RESTORE option in user programming is selected for that 
zone.  
To RESTORE an alert, see Section 3.7. 

 

Содержание SigNET 200

Страница 1: ...SigNET 200 300 User Guide E LAB 1543 1 SigNET 200 300 User Guide...

Страница 2: ...7 When changing or installing expanders on the SigNET 200 300 system always ensure that all anti static precautions are adhered to while handling connectors wires terminals and PCBs Europlex Technolog...

Страница 3: ...ORCE SETTING THE SYSTEM 7 3 6 UNSETTING THE SYSTEM 7 3 7 RESTORING AN ALARM ACTIVATION ALERT 7 3 8 USING X10 FEATURES 8 4 USER MENU OPTIONS 8 4 1 ISOLATING A ZONE OR FAULT 8 4 2 INHIBITING A ZONE 9 4...

Страница 4: ...SigNET Keypad may be factory fitted with a Portable ACE PACE proximity device reader and or a wireless module for the enrolment of wireless sensors Figure 1 SigNET Keypad Table 1 LED Status Indicators...

Страница 5: ...advances the user through the menus in the same way as pressing the SELECT option right soft key When no more menu options can be selected this key has no function In data entry mode press this key to...

Страница 6: ...user should exit the building When the system has been fully set the LCD displays FULLSET on the bottom line for approximately 10 seconds If the alarm fails to set see Section 3 4 Failing to Set the S...

Страница 7: ...age PANEL DISARMED is displayed on the Keypad for approximately 5 seconds 4 The source of the alarm condition is displayed on the Keypad and the Alert LED flashes The Keypad continues to display the a...

Страница 8: ...ilable to users through the navigational menus on the Keypad In navigation mode the user selects one of a number of pre defined programming options from a list Pressing the up down arrow keys scrolls...

Страница 9: ...e with fewer numbers than it is set to receive To change a user code 1 Enter the current user code 2 Using the up down arrow keys scroll to the MENUS option and press SELECT right soft key 3 Scroll to...

Страница 10: ...he left and right arrow keys Press ENTER right soft key to save the new date If an attempt is made to save an invalid date value the text INVALID VALUE is displayed for 1 second and the user is prompt...

Страница 11: ...system on the bottom line and all previous events are displayed for 1 second in turn 5 To view an event from a particular date enter the date with the numeric keys 4 8 Enabling the Chime Function The...

Страница 12: ...se profiles are defaults and can be changed 7 Enter the user code that will be assigned to the new user and press SELECT right soft key 8 The Keypad confirms that the new user has been created Editing...

Страница 13: ...of this mode An exit timer can be applied to this mode by enabling the Partset A timed variable To perform a PARTSET A see Section 3 2 PARTSET B Standard Master The PARTSET B option applies protection...

Страница 14: ...event log when reporting system events To set the date and time see Section 4 5 TEST Standard Master This menu option provides the following test features 1 Bell test The bell test activates the exte...

Страница 15: ...SigNET 200 300 User Guide E LAB 1543 15 Zone Chart Zone Description...

Отзывы: