LUBE-MASTER R10
7(21)
TCM: ‡
TCM MainMenu
PortX: ‡
TCM MainMenu
Mask:X ‡
Set Mask 0-15
Mask:X ‡
Set Mask 0-15
Mask:X ‡
Set Mask 0-15
TCM: ‡
TCM MainMenu
PortX: ‡
TCM MainMenu
Tank:X ‡
Set TankNo ???
Tank:X ‡
Set TankNo ???
Hint!
Follow preferably ”Recommendation for setting addresses” when setting addresses.
4.5. Recommendation for setting addresses
Each module demands a unique 16 bit hexadecimal address. There are
some forbidden and some reserved addresses but it is possible to use
all addresses between 0001 and 9999. To make it easier to upgrade
and support the system we recommend using the chart to the right.
This means that the first TSM should have the address 8001 and the
next one 8002 etc. It is a good idea not to use the default address
8000, it makes it easier to add new Tam’s
NOTE! It is essential to add modules to the configuration sheet
continuously as they are configured to avoid collisions.
NOTE!
Address 0000 is forbidden and addresses above 9999 are reserved for the system.
5. Configure the ports
A TSM has four ports that are used to control four different pumps/tanks.
5.1. Connect a tank to a port
[TCM//PortX/Tank]
To set a tank number for a port, from the main menu.
Enter menu
[TSM//PortX]
by scrolling with
or
.
At
PortX:
press
ENTER
.
Press
ENTER
to get the cursor.
Check the number of the tank that is connected to portX, type that number in and
press ENTER to acknowledge. When the cursor disappears it is finished.
Press EXIT two times to leave Set-Up mode.
5.2. Set the Mask
[TCM//PortX/Mask]
Using the Mask each tank function can be set. This is done by
adding the values for the desired functions, in the chart to the right.
EXAMPLE:
Port 1 measures the level of a waste oil tank and
controls the air to a waste oil pump using an Eurolube 2-levels
sensor 53132. This is up done by calculating the value of the Mask 1+4+8=13. The
Mask should be set to 13.
Enter menu
[TCM//PortX]
by scrolling with
or
.
At
PortX:
press
ENTER
.
Scroll to
Mask:
using
or
.
Press
ENTER
to get the cursor.
Type the
mask value
and press
ENTER
to acknowledge. When the cursor
disappears it is finished.
Press
EXIT
two times to leave Set-Up mode.
Adress
Module
0000
Forbidden
1000 – 1xxx
MPDM
2000 – 2998
PM
2999
PC-database
3000 – 3xxx
KeyPad
4000 – 4xxx
LED-display
5000 – 5xxx
PLC-modules
6000 – 6xxx
Reserved
7000 – 7xxx
Reserved
8000 – 8xxx
TCM
9000 – 9xxx
Others
A000 – FFFF
Forbidden
Function
Value
Waste oil tank
1
Not in use
2
Invert B
4
Invert A
8