4(21)
The other three connectors are used to connect external devices without a power source such as a Printer Module
(PM), a LED Module (LED) and/or a KeyPad (KP). These connectors can only supply power to a single device. For
more detailed information see the
LUBE-Master Manual
NOTE! If the communication loop begin in one of these modules it must be connected to either MPDM IN or
MPDM OUT or +24V must not be connected.
The RESET-button
(B)
can be used to reset the module or reset the module address.
Power supply is connected to the connector
(C)
.
NOTE!
Check polarity, GND is closest to the hole!
The connector
(D)
is used when you install a chassis-mounted key switch and
diode. With the key switch you can set the status of the module to OFF-,
NORMAL-, or OVERRIDE-mode. The diodes indicate setting.
There are four connectors
(E)
24 V, OC, A, B and GND, one
for each pump/tank. Solenoid valves and level sensors are connected
to these connectors.
“A” of a TSM port is connected to “order oil/emptying” of the level
sensor.
“B” of a TSM port is connected to “Stop level” of the level sensor.
“GND” of a TSM port is connected to common of the level sensor.
“+24V” of a TSM port is connected to one of the terminals of a
solenoid valve and “Sol” is connected to the other.
TIP!
If a TSM is used for a tank containing flammable liquid it could be necessary to use an EX
protection.
There are two diodes
(F)
for every port. These indicate the status of entry points A and B, the level in the tank.
One diode
(G)
on each port indicates if the solenoid valve is open or not.
If the diode
(H)
is flashing the
module is operational and
working properly. A steady
light or completely off indicates
a problem.
DIL switches for termination
and BIAS are located at
(I). (J)
Shows the position of the
replaceable communication
driver. The
SetupLock
jumper
at position
(K)
has no function
for a TSM.
A LED
(L)
shows if an
analogue sensor is detected or
not, lit if detected. The analogue
sensors are connected to the 2-
pole connectors marked
(M)
.
The polarity is marked on the
PCB.
TSM200
PCB 203 02 91X
with chip TSM 2.xx.xx.
ALARM
Solenoid valve
STOP
+24 V
A
GND
B
Sol