5(21)
3.2. Connection adapter (203 03 17)
To simplify the connection of the level sensors and the pump controllers there are a connection adapter inserted in
the main board port connectors. It splits each port connector into two identical connectors, one for the indicator
board in the lid and one for the level sensors and pump controllers.
This enables the possibility to fully remove the lid in an easy way but still keep the control functionality of the
module.
3.3. Lid indicator board (203 03 03)
By the indicator board mounted in the lid of the module the status of the discrete level sensors and the pump control
can be seen from the outside.
The indicator board is powered by the Port 1 inter connection cable. If the board has power (24VDC) the power led
(see picture) will be lit.
The 8-pole SIL-switch block can be used to invert the LED output compared to the sensor/pump signal. This can be
used depending on the NC/NO of the sensor and pump control used.
The SIL-Switch stock default for TSM 53430 is all ON. This is shown by the text to the left of the switch block in
the right picture above.
NOTE ! Never disconnect or connect the lid indicator board when power is on. Doing that could cause
damage to the lid indicator board.