00092402.DOC, Version 1.1
39/55
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable Pin
International
Brown Live
L
Blue Neutral
N
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
The device is equipped with a lockable power input connector. Plug in the power cord and turn it to the right
until it locks. Plug the power cord into a grounded electrical outlet that matches the rated voltage of the
machine.
Connection between devices
On the rear panel, there is a socket (Power Out). Connect the output with the mains input of the next fixture
until all fixtures are connected.
Please note:
A maximum of 8 EUROLITE
Zeitgeist PMC-16 MOVE
may be linked together. After every 8
devices, the fixtures must have a renewed connection with the power mains.
OPERATION
After you connected the spot to the mains, the EUROLITE
Zeitgeist PMC-16 MOVE
starts running. During
the reset, the motors are trimmed and the device is ready for use afterwards.
The device can be operated in stand-alone mode via LCD display with operating buttons, in DMX-controlled
mode via a lighting controller or via Art-Net via media servers.
Stand-alone Mode
In the stand-alone mode, you can do without a controller. Disconnect the EUROLITE
Zeitgeist PMC-16
MOVE
from the controller and call the internal program.
Please refer to the instructions under Control Board.