![EuroLite ZEITGEIST PMC-16 MOVE Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/eurolite/zeitgeist-pmc-16-move/zeitgeist-pmc-16-move_user-manual_2438402036.webp)
00092402.DOC, Version 1.1
36/55
The fixture’s base enables to be mounted in two ways.
The Moving-Head can be placed directly on the
stage floor or rigged in any orientation on a truss
without altering its operation characteristics (see
the drawing).
For overhead use (mounting height >100 cm),
always install an appropriate safety bond.
You must only use safety bonds complying with
DIN 56927, quick links complying with DIN 56927,
shackles complying with DIN EN 1677-1 and BGV
C1 carbines. The safety bonds, quick links,
shackles and the carbines must be sufficiently
dimensioned and used correctly in accordance with
the latest industrial safety regulations (e. g. BGV
C1, BGI 810-3).
Please note:
for overhead rigging in public or
industrial areas, a series of safety instructions have
to be followed that this manual can only give in part. The operator must therefore inform himself on the
current safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Install the safety bond by inserting the quick link in the hole on the bottom of the base. Pull the safety bond
over the trussing system etc. Insert the end in the quick link and tighten the fixation screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
Installation via the adapter plate
Screw both clamps via a M10 screw and self locking nut onto the
respective holes in the adapter plate.
The clamps may either be installed horizontally or vertically.
Insert the four quick-lock fasteners of the adapter plate into the
respective holes on the bottom of the device. Tighten the quick-lock
fasteners fully clockwise.
(1)
Adapter plate
(2)
Clamp
(3)
Safety-rope
(4)
Quick-lock fastener