00112264.DOCX, Version 1.1
20/28
INSTALLATION
WARNING! Risk of injury caused by falling objects
Devices in overhead installations may cause severe injuries when crashing down. Make sure
that the device is installed securely and cannot fall down. The installation must be carried out by
a specialist who is familiar with the hazards and the relevant regulations.
DANGER! Damage caused by laser radiation
Observe the chapter safety instructions when installing the device.
The device may be placed on the floor or fastened to a truss or similar rigging structure. The device must
never be fixed swinging freely in the room.
1
The rigging structure must support at least 10 times the weight of all fixtures to be installed on it.
2 Block access below the work area and work from a stable platform when installing the device.
3 Use rigging hardware that is compatible with the structure and capable of bearing the weight of the
device. Please refer to the “Accessories” section for a list of suitable rigging hardware.
4 Secure the device with a safety bond or other secondary attachment. This secondary safety attachment
must be sufficiently dimensioned in accordance with the latest industrial safety regulations and
constructed in a way that no part of the installation can fall down if the main attachment fails. Pull the
safety bond through the safety eyelet and fasten it in such a way that, in the event of a fall, the maximum
drop distance of the device will not exceed 20 cm.
5 To align the device, release the fixation screws at the mounting bracket, adjust the desired inclination
angle and retighten the fixation screws.
6 Make sure not to point the laser beams at highly reflective surfaces such as mirror balls, windows and
shiny objects. As a precaution, remove or cover up highly reflective objects in order to avoid laser
reflections.
7 After installation, the device requires inspections periodically to prevent the possibility of rot, deformation
and looseness.
Mounting bracket
Truss mounting clamp
Safety bond
Fixation screw