00064545.DOC, Version 1.0
19/23
A safety bond which already held the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
DMX512 control
The wires must not come into contact with each other, otherwise
the devices will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used.
Only use a DMX cable and 3-pin XLR plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR connection:
If you are using controllers with this occupation, you can connect the DMX output of the controller directly
with the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other
XLR outputs, you need to use adapter cables.
Building a serial DMX chain:
Connect the DMX output of the first device in the DMX chain with the DMX input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution:
At the last fixture, the DMX cable has to be terminated. Plug the terminator with a
120
resistor
between Signal (–) and Signal (+) in the DMX output of the last fixture.
Connection between devices
On the rear panel, there is an IEC socket (Power Out). Connect the output with the input of the next fixture
until all fixtures are connected.
Attention:
It is recommended to renew the connection with the power mains after every
8
devices.