00127887, Version 1.0
27/40
INSTALLATION
Overhead rigging
WARNING! Risk of injury caused by falling objects
Devices in overhead installations may cause severe injuries when crashing down. Make sure
that the device is installed securely and cannot fall down. The installation must be carried out by
a specialist who is familiar with the hazards and the relevant regulations.
The device may be fastened to a truss or similar rigging structure via the mounting bracket using appropriate
clamps. The device must never be fixed swinging freely in the room.
1
The rigging structure must support at least 10 times the weight of all fixtures to be installed on it.
2
Block access below the work area and work from a stable platform when installing the device.
3
Use rigging hardware that is compatible with the structure and capable of bearing the weight of the
device. Please refer to the “Accessories” section for a list of suitable rigging hardware.
4
Secure the device with a safety bond or other secondary attachment. This secondary safety attachment
must be sufficiently dimensioned in accordance with the latest industrial safety regulations and
constructed in a way that no part of the installation can fall down if the main attachment fails. An
appropriate eyelet is mounted on the device for fixation of the safety rope. Fasten the safety rope in such
a way that, in the event of a fall, the maximum drop distance of the device will not exceed 20 cm.
5
To align the device, release the fixation screws at the mounting bracket, adjust the desired inclination
angle and tighten the fixation screws.
6
After installation, the device requires inspections periodically to prevent the possibility of corrosion,
deformation and looseness.
Mounting on a stand
For mobile use, place the light set on a stand via the rear sleeve and fasten
the fixation screw. Suitable stands can be found in chapter Accessories.
Notes:
•
Please make sure the load is installed in a balanced way and the carrying
capacity of the stand is not exceeded.
•
Install the stand on a plane area (inclination angle max. 5°) and out of the reach
of people.
•
Depending upon the individual installation spot, all necessary measures to
prevent displacement or tilting (also in case of fire) have to be taken.
MIC
POWER IN
POWER OUT
USB
DMX IN
DMX OUT
ON/OFF
SAFETY
HOOK
25% 50% 75% 100%