EUROHEAT
DISTRIBUTORS (H.B.S) LTD.Aug 2006
Instructions Part number IN1016 Ed G
11
Gas Control Valve
6
4
2
Manual control.
Disables the thermostatic
control of the stove and
allows the stove to operate
at any chosen setting.
Thermostatic control.
Allows the stove to be controlled
by the room temperature,
maintaining a constant ambient
temperature.
Ignition Button.
Pushing the button energizes
the electronic spark generator to
produce a pulsed sparks to ignite
the pilot flame.
Sit Gas Valve Eurosit 630
a)
(see operating instructions for full details) Ignition is by battery spark, ensure battery is fitted.
Ensure control knob is in the off position. Push in the control knob and turn to the pilot position,
keeping the knob depressed. Press the ignition button. The pilot should now be alight after the
system has been purged. Keep the knob depressed for 20-30 seconds, when the knob is released
the pilot should stay lit. It may be necessary to repeat the procedure if the pilot does not light,
particularly when the fire is first used.
b)
With the pilot burning, turn the control knob clockwise, this will turn the main burner on.
c)
In the unlikely event of the flame being extinguished whilst the gas control is in the “on”
position, immediately turn “off” and wait 2 minutes before attempting to relight.
For full operating instructions see operation manual.
Lighting