EUROHEAT
DISTRIBUTORS (H.B.S) LTD.Aug 2006
Instructions Part number IN1016 Ed G
3
Harmony 5 Stanford 50 Gas Conventional Flue
Model Number
49991
Heat Output Maximum
4.8 kW/hr (16,377 BTU)
Heat Output Minimum
1.9 kW/hr (6482 BTU)
Gas Input Maximum
6 kW/hr (20472 BTU)
Gas Input Minimum
2.5 kW/hr (8530 BTU)
Heat Control
Thermostatic and Manual
Fuel Types
Natural Gas or L. P. G.
(Specify at time of order)
Efficiency
80% + (net)
Ignition Type
Battery Spark
Pilot Flame
Yes
Flame Failure
Yes
Flue Spillage Sensor
Thermocouple Interrupter (TTB)
Fuel Effect Type
Coal
Fuel Outlet Options
Top or Rear (Top pre fitted)
Flue Size
4” (100mm) Internal Diameter
Warranty
Standard 1 Year
Colour Options
Cast Black, Satin Black Enamel,
Bottle Green Enamel, Blue Enamel
Decorative Plinth
Optional Extra
Technical Data with Eurosit Gas Valve 630
Gas
Type
S y s t e m
Pressure
Main
B u r n e r
Nozzle
Nominal Output
(Maximum operation)
Minimum Output
(Low operation)
Pilot
N o z z l e
size
Low
Operation
By Pass
Heat
Output
Gas
Input
Hourly
Input
Burner
Operating
Pressure
Hourly
Input
Burner
Operating
Pressure
G20
Natural
Gas
20mbar
1 jet
4 x 1.11
0.64
m³/h
9.7mbar
0.266
m³/h
1.5mbar
37
1.70
5kW/hr
17,060
BTU/hr
6kW/hr
20,472
BTU/hr
G31
Propane 37mbar
1 jet
4 x 0.66
0.477g
32.5mbar
0.193kg
5.5mbar
23
1.11
5kW/hr
17,060
BTU/hr
6kW/hr
20,472
BTU/hr
6
4
2
Seasonal Efficiency
The efficiency of this appliance has been measured as specified in BS EN 613:213 and the result is
72% Nat Gas and 73.7% LPG. The gross calorific value of the fuel has been used for this efficiency
calculation. The test data from which it has been calculated has been certified by BELTEST. The
efficiency value may be used in the Governments Standard Assessment Procedure (SAP) for energy
rating of dwellings.