13 Maintenance, cleaning, testing the stove
All cleaning operations and tests must be carried out when the stove is cold, with the plug disconnected,
using gloves and mask. The ZF company does not assume civil or criminal liability, in case you clean or test
the stove when this is on, still warm, with the voltage supply switched on and without proper protective
equipment.
Daily Cleaning
Tools required:
1) Ash vacuum cleaner
2) Screwdriver
3) Brush
4) Extract scraper lever
Open the door of the stove, by an ash vacuum cleaner remove all the
ash, with a brush, clean the remains attached to the inner sides of the
stove.
Remove and clean carefully the brazier of the stove.
Brazier Cleaning
The cleaning of the brazier is very important for the proper
operation of the stove; it should be performed daily before each
start. Lift the brazier from its place, clean the inside of the brazier
with a brush by removing combustion remains and free all the
air passages with a screwdriver or a pointed tool (not supplied
with the stove). This operation is particularly necessary when
using a pellet of poor quality; it is also good to check and clean
the brazier support, if there are remains inside they should be
removed with a shovel or with an ash vacuum cleaner. A good
cleaning of the brazier ensures good combustion and,
consequently, a high yield of the stove.