ETS REJUVASUN 332 Скачать руководство пользователя страница 4

28940-01A

iii

afety Information

Ultraviolet radiation. Follow instructions. Avoid overexposure. As with natural sunlight, overexposure can cause
eye and skin injury and allergic reactions. Repeated exposure may cause premature aging of the skin and skin

cancer. WEAR PROTECTIVE EYEWEAR; FAILURE TO MAY RESULT IN SEVERE BURNS OR LONGTERM INJURY TO THE EYES.
Medications or cosmetics may increase your sensitivity to the ultraviolet radiation. Consult physician before using sunlamp if you are
using medications or have a history of skin problems or believe yourself especially sensitive to sunlight. If you do not tan in the sun, you
are unlikely to tan from the use of this product. Children, the elderly, or fair skinned people who always burn easily and either never tan
or tan minimally should not use this equipment.

To use, lie down under canopy and pull down as far as adjustment will allow. Minimum use distance from face tanner is 4 inches (10.2
centimeters), otherwise overexposure may occur. Minimum use distance elsewhere is touching the clear plastic panels. Do not use with-
out clear plastic panels in place. Untanned persons should not tan on consecutive days during their first week of tanning. Never tan more
than once a day. Tanning normally appears after the first few sessions and maximizes after approximately four weeks. Tan once or twice
per week thereafter to maintain appearance. Persons already having a base tan may begin at advanced levels corresponding to the
extent of their base tan.

New lamps emit approximately 10% more ultraviolet radiation during the first 50 hours of operation. Recommended tanning times should
therefore be reduced by approximately 10% during that period.

WARNING:

• Read the instructions booklet before using this sunlamp product. • All persons in the room should wear protective eyewear

when lamps are on. Required eyewear: Ultra SunGlobes®, 

special-eyez, or other dark-tinted eyewear that meet 21 CFR 1040.20 guide-

lines. Other types of eyewear may not provide adequate protection. Failure to use protective eyewear may result in severe burns or other
eye injury. If discomfort develops, discontinue use and consult a physician.

ONLY THE FOLLOWING LAMPS HAVE BEEN CERTIFIED FOR USE IN THIS EQUIPMENT:

Velocity® Wolff® Model VEL71-T12 / 100W PREHEAT-BIPIN

(Bench lamps)

Velocity® PLUS Wolff® Model VLP71-T12-100W Bi-Pin

(Canopy lamps)

Heraeus E400 HPT

-or- 

Philips Model HPA 400/30s

-or- 

CosmoTech Model 23045

(SolarMax™ IFT facial unit)

THIS EQUIPMENT MUST BE EARTH GROUNDED. 

This product is in conformity with performance standards for sun lamp products under 21 CFR PART 1040.20 and
ANSI/UL Standard 482. Certified to CAN/CSA Standard C22.2 NO. 224.

LABELING NOTICE:

Labels are affixed on all systems to inform the user of possible dangers. Regulations are stated in 21 CFR, Section

1040.20, and require that all products manufactured after September 8, 1986 which use sunlamps must display the following:

DANGER

88465

RECOMMENDED EXPOSURE TIMES IN MINUTES

MAXIMUM EXPOSURE TIME IS 20 MINUTES

Level 1/Week 1

Level 2

Level 3

Level 4

Level 5

Skin Type:

1st-3rd Sessions

I

Sensitive Skin

(Burns easily and severely and does not tan.)

NOT RECOMMENDED FOR TANNING

II

Light

(Burns easily and severely and tans minimally.)

4

8

12

16

20

III

Normal

(Burns moderately and tans average.)

6

10

15

20

20

IV

Dark

(Burns minimally, tans easily and above average.)

8

12

16

20

20

DISCONNECT POWER BEFORE ATTEMPTING TO CLEAN, RELAMP, OR ENGAGE IN THE MAINTENANCE OF THIS PRODUCT.

Содержание REJUVASUN 332

Страница 1: ...28940 01A...

Страница 2: ...by this warranty Warranty coverage does not include cosmetic abnormalities such as scratch es nicks dents or other cosmetic changes that do not materially interfere with the function of the tanning un...

Страница 3: ...nstalling and using the unit Always be sure to observe all safety precautions ontents Safety Information iii Installation 1 Unpacking and Inspection 1 Pre Installation Planning 2 Hardware Inventory 3...

Страница 4: ...uld therefore be reduced by approximately 10 during that period WARNING Read the instructions booklet before using this sunlamp product All persons in the room should wear protective eyewear when lamp...

Страница 5: ...ines Les personnes qui ont d j un teint h l peuvent commencer des niveaux plus lev s selon l im portance de leur h le initial Les lampes neuves mettent approximativement 10 de plus de rayons ultraviol...

Страница 6: ...the ballast drawer with a Phillips screwdriver Note The cartons are reusable You may wish to save them for future use After unpacking the unit check to make sure you have received the following Canopy...

Страница 7: ...CAUTION Use of a voltage source above 230V AC may prevent proper operation of the sunbed and could cause damage and void the warranty CAUTION Proper assembly of your sunbed requires three people Plan...

Страница 8: ...2 Retaining Ring Quantity 2 Phillips Screw 10 x 1 2 Quantity 8 Phillips Screw 10 x 1 Quantity 8 Hardware Inventory Open the hardware bag Remove the hardware In addition to a phone type RJ 11 cable and...

Страница 9: ...ar shift it to the left or right and then pull it from the bed After the bed is assembled reinstall the bar to keep the tray from damaging the access panel if the bed is moved Stand Assembly 1 Place t...

Страница 10: ...protect the units and place the canopy on the bench with the canopy hinge arms toward the back Once again do not use the canopy plastic endcaps to lift the unit CAUTION DO NOT lift the canopy using th...

Страница 11: ...embly Procedures 2 Insert the Nylon Floating Bearings into the canopy hinge arms and carefully lower the hinge arms into the bench uprights 3 Secure the arms in place with the Hinge Pins and Hinge Pin...

Страница 12: ...up as shown 2 Have a helper hold the canopy in its fully open position 3 The lower clevis forks are already installed Make sure the threaded hole faces up slide the Gas Springs down into the bench upr...

Страница 13: ...s Forks Pay special attention when lowering the canopy that the clevis forks do not damage the bronze bushings Bronze is excel lent for smooth pivoting applica tions such as this but tends to be soft...

Страница 14: ...ructions for installing the fan are included with the body fan kit Follow those instructions to install the body fan Put the head end endcap the one without slots on top in place and secure with two 1...

Страница 15: ...the RJ 11 phone type cable between the canopy and rear jack on the ballast drawer The three jacks on the front of the drawer are for remote connections Connect main power cord as described in Pre Ins...

Страница 16: ...p of the ballast drawer It simply sits on the drawer over the air slots and is held in place by airflow when the unit is running The arrow on the filter should point down Reinstall the Ballast Tray St...

Страница 17: ...e of the RJ 22 remote control ports Your sunbed will not operate without the Remote Control Bypass plug or a remote system connected ATTENTION Although the Remote Control Bypass plug provided with you...

Страница 18: ...auto addressing feature of the Manager and the following parameters 5 6 7 8 9 10 15 and 23 See your T Max manual for descriptions of these parameters and how they function Special Note on T Max The R...

Страница 19: ...allations the T Max 3W can offer the same control as the T Max Manager Pro eliminating the need for a Manager The remote control bypass plug must not be used in this configuration The 3W may be used a...

Страница 20: ...ro and one G2 to each wireless ready tanning bed The rest of the salon may be daisy chained together and connected to the Manager Pro After you have set the T Max 3W s address to 0 refer to your T Max...

Страница 21: ...f you are using a T Max 3W as a master remote the id of the sunbed must be set to 1 If you are using a T Max Manager Pro each sunbed must be assigned a different id To set the id press the timer butto...

Страница 22: ...ver tan more than once a day Tanning normally appears after the first few sessions and maximizes after approxi mately four weeks Tan once or twice per week thereafter to maintain appearance Persons al...

Страница 23: ...an control Controls the speed of the body fan during use D Body fan speed indicator Indicates speed of fan OFF LOW MED HIGH E Timer display Displays remaining time F Stop button Interrupts tanning ses...

Страница 24: ...c shield The cooling fans run for a period of time after the lamps shut off to aid in cooling the sunbed The timer will indicate as a reminder to clean the sunbed After the sunbed is cleaned press the...

Страница 25: ...ent Step 2 With a soft cloth wipe the entire length of each lamp to remove any film buildup Step 3 Clean both sides of the acrylic shields with a non ammonia dis infectant cleaner Step 4 Wipe the refl...

Страница 26: ...ning Replacing Acrylic Shields The acrylic shields are secured in place by turn latches along the front edge Use a flat bladed screwdriver to turn the latches a quarter turn to open the acrylic The ac...

Страница 27: ...ps is a viola tion of Federal regulations and will void your warranty These lamps have an aver age life of 700 1000 hours of effective tanning use Lamps used longer than that begin to lose their effec...

Страница 28: ...new lamp using a clean cloth or paper towel Ensure that the lamp is firmly seated in the lamp holders Note Never take hold of the lamp such that your fingers are in contact with the lamp glass Finger...

Страница 29: ...does not replace old lamp NOTE Gas springs are manufactured to hold the canopy in its fully open position as well as allow it to rest fully closed If left open for an extended period of time some cre...

Страница 30: ...Contact servicer Current sensor indicating unit is on when it should be off Contact servicer Requested session time exceeds maximum time allowed 1 Bypass plug is not installed see Electrical Connecti...

Страница 31: ...ce has not been set 2 The sunbed has not been connected to the remote system see Remote Connections 1 Delay time of T Max Manager has not been set 2 Delay time has expired and session has begun Auto s...

Страница 32: ...28940 01A T 332 3F LUX...

Страница 33: ...28940 01A Ballast Tray...

Страница 34: ...apacitor 75 F Contactor Contactor for Face Tanner Cover Canopy Current Sensor Endcap Endcap Canopy Head End Endcap with Body Fan Cut outs Face Tanner Assembly Outer Fan Body Fan Cooling Fan Grill Plas...

Страница 35: ...terior E Check Clean Fans F Change Lamps H Check Fasteners nuts bolts etc I Check Power Cords J Change Filter See Care and Maintenance See Lamp and Acrylic Replacement Fans are located on top of the c...

Страница 36: ...ardwire Main Lamps bench Velocity Main Lamps canopy Velocity PLUS Ballasts 100W Face Tanner SolarMax IFT FT Ballasts 400W Body Cooling System Full side fan panel plus 230cfm Turbo Timer System Digital...

Отзывы: