EOZ installation guide
7. Setting Ozone Module addresses
All Ozone Modules connected to the same Control Panel must be set to a unique device address. The Ozone
Module(s) inside of an EOZ chassis have been set at the factory to the following specifications:
EOZ-1: Device address is “3”
EOZ-2: Device addresses are “1” and “2”
For installations with multiple EOZ units, it is important to ensure that there are no overlapping address conflicts:
* All Ozone Modules in each EOZ chassis or canopy must have a unique device address.
* Address identification labels must be added to the service hatch on EOZ units. In case of model EOZ-2, both
address labels must be placed upon the unit.
Opening EOZ hatch
Start by opening the front panel by opening two (2) clamps that are holding the panel.
NOTE
! The following section applies only when installing multiple EOZ units. If installing only one unit,
the Ozone Module addresses do not need to be changed and you may skip this section.
NOTE
! Turn off and disconnect the electrical power cord from the EOZ chassis before proceeding.