For Support Contact +46 8 25 28 75, [email protected] or +61 2 9956 7377, [email protected]
Internal Serial
– setting the baud rate
The baud rate for the wireless modem can be set in this section. As default the unit is set to a
baud rate of 115200.
•
Module
→
MCU should match MCU
→
Port.
•
MCU
→
Port sets the serial port on the device and should be adjusted to suit your device
connected to the port.
•
For "Flow Control", currently only CTS is supported.
For a baud rate of 9600, 57600 or 115200, the MCU will use a feature called "auto baud" to
adjust to the correct baud rate. For other baud rates, the internal module must be
reconfigured manually.
To adjust the baud rate manually for the internal engine/module (PLS62-W), use the AT+IPR
command:
•
Send ETSC1 in the terminal window to change to AT-command mode.
•
Send AT+IPR=xxx, where xxx is the desired baud rate (e.g. AT+IPR=115200).
•
Send --- to return to ET-command mode and continue programming the unit.