Settings of the ETL Interface
Instruction Manual ATS 400 with SC-NG
Version 4.03
52
Symbol
Name
Limits
Annotation
T
1
Testtime
> 200 ms
Time from start of one test until the
start oft he next test.
T
2
Response time > 18 ms
Necessary minimum time to recognize a
change in the start signal.
T
3
Result time
10 ms – 10 s
Time the result will be available.
Calulate the time according tot he
formula: T
3
= T
Zyklus
+ 18 ms, where
T
Zyklus
is the cycle time of the polling.
Round up the value tot he next multiple
of 10 ms.