Settings of the ETL Interface
Instruction Manual ATS 400 with SC-NG
Version 4.03
49
10.2
Enabled
Using this setting the output will be active until the next devcie under test will
tested. With this setting each test step can be started with the start signal.
Symbol
Name
Limits
Annotation
T
1
Testtime
> 200 ms
Time from start of one test until the
start oft he next test.
T
2
Response time > 18 ms
Necessary minimum time to recognize a
change in the start signal.