ENVR208
Step 4
Check
Enable Line Crossing Detection
checkbox.
Step 5
Optionally, check
Save VCA Picture
to save the captured pictures of line crossing detection.
Step 6
Follow the steps to set the line crossing detection rules and detection areas.
1)
Select an Arming Region to configure. Up to 4 arming regions are selectable.
2)
Select the Direction as A<->B, A->B, or A<-B.
A<->B
: Only the arrow on the B side shows. When an object goes across the configured
line with both direction can be detected and alarms are triggered.
A->B
: Only the object crossing the configured line from the A side to the B side can be
detected.
B->A
: Only the object crossing the configured line from the B side to the A side can be
detected.
3)
Drag the Sensitivity slider to set the detection sensitivity. Sensitivity range: sensitivity.
The higher the value is, the more easily the detection alarm can be triggered.
4)
Click Draw Region and set two points in the preview window to draw a virtual line.
Step 1
Set the arming schedule. Refer to Chapter 11.1 Configure Arming Schedule.
Step 2
Set the linkage actions. Refer to Chapter 11.2 Configure Alarm Linkage Actions.
Step 3
Click
Apply
.
12.4 Intrusion Detection
Purpose:
Intrusion detection function detects people, vehicle or other objects which enter and loiter in a
pre-defined virtual region, and some certain actions can be taken when the alarm is triggered.
Step 1
Go to
System > Event > Smart Event
.
Step 2
Click
Intrusion
.
Содержание ENVR208
Страница 1: ......
Страница 44: ...ENVR208 Result You can view all of the channels in one screen using the CMS or web browser ...
Страница 108: ...ENVR208 Figure 11 12 Alarm Output ...
Страница 131: ...ENVR208 Figure 14 8 Set Trigger Cameras of POS Step 8 Click Apply ...
Страница 140: ...ENVR208 Figure 15 8 Port Settings ...
Страница 167: ...ENVR208 Chapter 19 Appendix 19 1 Specifications ...
Страница 196: ...Made in PRC Imported by Velleman Group nv Legen Heirweg 33 9890 Gavere Belgium www velleman eu ...