PART NO. 

24861 

REV 

A.0

INSTALLATION AND OPERATION MANUAL  |  

SPECIFICATIONS

GENERAL

Area of use

Nonhazardous locations

ENCLOSURE

Protection
Cover attachment

Polycarbonate with machine screws

Entries

1 x 3/4" entry (bottom)

Material

Polycarbonate

Mounting

Pole mount

Dimensions

4.6" (W) x 6.1" (H) / 117mm (W) x 155mm (H)

CONTROL

Supply voltage

ETI PN 24781:   24VAC; 50/60 Hz

Load

3 amp maximum inductive

3 amp maximum resistive

Heater Hold-On timer

0, 1, 3 (default) or 5 hours; configured by magnetic reed switch

Set point temperature

Off (moisture only), 36°F, 38°F (default), 38°F; 

configured by magnetic reed switch

INTERFACE

Status indicators

SUPPLY (green): Power on; will flash while in configuration mode

HEAT (yellow): Heating cycle in progress

WIRE AND CABLE RATINGS

Power cable

Size for heater load (16 amps maximum)

Heater cable

Size for maximum heater load

ENVIRONMENTAL

Operating temperature

–40°F to 104°F (–40°C to 40°C)

Storage temperature

−67°F to 167°F (−55°C to 75°C)

ORDERING INFORMATION

Order Number

Description

24781

LCD–8, 24VAC

18703

Red Wire Nuts (QTY 4)

24861

LCD–8 Manual (QTY 1)

Содержание SNOW SWITCH LCD-8

Страница 1: ...ngle point of disconnect Size the circuit breaker in accordance with the size of the expected load The maximum current load for the LCD 8 is 3 amp resistive for 24 VAC Electrical Shock Fire Hazard CON...

Страница 2: ...enclosure Verifying system functionality after installation or when troubleshooting used to require spray circuit cooler or ice for controller activation The Sno TestTM feature eliminates this need b...

Страница 3: ...that it may be correctly processed upon receipt at Environmental Technology For more information about replacement parts or for a replacement Data Sheet or Manual please visit http www networketi com...

Страница 4: ...s off and the cup heaters energize for ten seconds Finally both are off for another ten seconds During this time the green LED blinks slowly one 1 second on one 1 second off Normal operation follows W...

Страница 5: ...ve 17 F but it enters the Lockout state instead if the temperature is below 17 F Additionally this Lockout state is entered if the temperature falls below 17 F during an automatic hold on cycle If the...

Страница 6: ...across this switch Figure 6 to start a hold on cycle or to terminate a running hold on cycle The magnetic switch determines whether the user s action swipes or holds the magnet during LCD 8 con gurat...

Страница 7: ...t is simply too cold to make operation practical The factory default low temperature lock out setting is Off meaning that the unit will try to activate the heaters regard less of ambient temperature S...

Страница 8: ...ensure sensing grid is dry and ambient air temperature is above 38 F 3 3 C then repeat this step 1 2 3 TO ENTER THE CONFIGURATION PROCESS The unit will ash the values of the three Field parameters in...

Страница 9: ...imer 0 1 3 default or 5 hours con gured by magnetic reed switch Set point temperature Off moisture only 36 F 38 F default 38 F con gured by magnetic reed switch INTERFACE Status indicators SUPPLY gree...

Страница 10: ...ressed or implied with respect to the contents of this publication or the products that it describes and speci cally disclaims any implied warranties of merchantability or tness for any particular pur...

Отзывы: