ETI SNOW SWITCH LCD-8 Скачать руководство пользователя страница 10

10

PART NO. 

24861 

REV 

A.0

INSTALLATION AND OPERATION MANUAL  |  

LIMITED WARRANTY

ETI’s two year limited warranty covering defects in 

workmanship and materials applies. Contact Customer Service 

for complete warranty information.

DISCLAIMER

ETI makes no representations or warranties, either expressed 

or implied, with respect to the contents of this publication or 

the  products  that  it  describes,  and  specifically  disclaims  any 

implied  warranties  of  merchantability  or  fitness  for  any 

particular purpose.

ETI reserves the right to revise this publication, and to make 

changes and improvements to the products described in this 

publication, without the obligation of ETI to notify any person 

or organization of such revisions, changes or improvements.

Copyright © 2020 ETI. All rights reserved.

Содержание SNOW SWITCH LCD-8

Страница 1: ...ngle point of disconnect Size the circuit breaker in accordance with the size of the expected load The maximum current load for the LCD 8 is 3 amp resistive for 24 VAC Electrical Shock Fire Hazard CON...

Страница 2: ...enclosure Verifying system functionality after installation or when troubleshooting used to require spray circuit cooler or ice for controller activation The Sno TestTM feature eliminates this need b...

Страница 3: ...that it may be correctly processed upon receipt at Environmental Technology For more information about replacement parts or for a replacement Data Sheet or Manual please visit http www networketi com...

Страница 4: ...s off and the cup heaters energize for ten seconds Finally both are off for another ten seconds During this time the green LED blinks slowly one 1 second on one 1 second off Normal operation follows W...

Страница 5: ...ve 17 F but it enters the Lockout state instead if the temperature is below 17 F Additionally this Lockout state is entered if the temperature falls below 17 F during an automatic hold on cycle If the...

Страница 6: ...across this switch Figure 6 to start a hold on cycle or to terminate a running hold on cycle The magnetic switch determines whether the user s action swipes or holds the magnet during LCD 8 con gurat...

Страница 7: ...t is simply too cold to make operation practical The factory default low temperature lock out setting is Off meaning that the unit will try to activate the heaters regard less of ambient temperature S...

Страница 8: ...ensure sensing grid is dry and ambient air temperature is above 38 F 3 3 C then repeat this step 1 2 3 TO ENTER THE CONFIGURATION PROCESS The unit will ash the values of the three Field parameters in...

Страница 9: ...imer 0 1 3 default or 5 hours con gured by magnetic reed switch Set point temperature Off moisture only 36 F 38 F default 38 F con gured by magnetic reed switch INTERFACE Status indicators SUPPLY gree...

Страница 10: ...ressed or implied with respect to the contents of this publication or the products that it describes and speci cally disclaims any implied warranties of merchantability or tness for any particular pur...