VII.Programming Tips/Trouble shooting 

 

The Programmer Displays 

“Programming Error”

 If the Programmer and MNPR™ are 

powered improperly or if the optical cable is mounted improperly, the Programmer 
will display, 

“Programming Error”

.   If you see this message make sure the 

Programmer and MNPR™ are powered in the proper sequence.  In addition, make 
sure the optical connector is securely mounted on front of the MNPR™ with the word 
Top facing up. 

 

Pressing buttons 

1, 4

 at the same time will reset the Programmer.  If the 

Programmer and MNPR™ were powered out of order and the 

“Programming Error”

 

message appears, try resetting the Programmer to see if that clears the error. 

 

VIII.Technical Support 

 

The ETI MNPR™ and Programmer are rugged units meant to be used in harsh 
conditions.  Nonetheless, they are not indestructible.  Do not drop, throw or 
submerge the Programmer (the MNPR™ is fully submersible).  With a minimum of 
care, the Programmer should have a long life span. 

 

Technical help for both the ETI MNPR™ and the MNPR™ Programmer is available 
from the following sources: 

 

Richards Manufacturing Co. Sales, Inc.   

Electronic Technology Inc, 

517 

Lyons 

Avenue 

       511 

Lyons 

Avenue 

Irvington, 

NJ 

07111 

       Irvington, 

NJ 

07111 

(973) 

371-1771 

        (973) 

371-5160 

FAX 

(973) 

371-4304       FAX 

(973) 

371-1929 

 [email protected] 

     [email protected] 

 

 
 

Содержание MNPR

Страница 1: ...MNPR Programmer Manual IM 7385 002 January 4 2000...

Страница 2: ...dly device Its operation is similar to that of a vending machine Specifically there are letters along the bottom and numbers along the right side of the Programmer face All of the features present on...

Страница 3: ...is being applied to only one phase the MNPR will scroll Network Voltage Too Low To Close This does not prevent the MNPR from being programmed 2 Connect the Programmer to the MNPR using the optical ca...

Страница 4: ...V Displays the version of the MNPR software 5 Mode Displays which of the four MNPR modes is currently active Sensitive standard Time Delay Insensitive or Watt Var 6 Reclose Voltage RV Displays the pre...

Страница 5: ...t Current called the Extended Delay 3 Insensitive Trip Press C 1 the MNPR closes the protector identically to Sensitive and Time Delay Mode The MNPR will open the protector only when the net power flo...

Страница 6: ...nd nothing happens your programmer may be set with the Actual Mode turned off Note Using Relay Actual to program the MNPR settings will not change the programmer s stored settings If the relay is set...

Страница 7: ...ote On 480 volt network protectors the MNPR maybe on the 120 volt side of the potential transformers In this case the display should be multiplied by 2 2 to calculate the actual network voltage B Netw...

Страница 8: ...he ETI_ _ Scroll will cause the MNPR to display Enter Program Password to proceed Because misuse of the Program command can result in damage to the MNPR and the network protector the password is not d...

Страница 9: ...ay XD This variable programs the Extended Delay used in Time Delay Mode and Insensitive Mode When the MNPR senses a trip condition it will wait this amount of time before issuing an open command 9 Ins...

Страница 10: ...want to reset the cycle counter Upon pressing ENTER the programmer will proceed to the next variable 5 Relay Fault FLT This feature allows the user to choose what action the MNPR will take if it malfu...

Страница 11: ...out of order and the Programming Error message appears try resetting the Programmer to see if that clears the error VIII Technical Support The ETI MNPR and Programmer are rugged units meant to be use...

Отзывы: