EW50 Industrial LTE Cellular Gateway
75
Address Auto-configuration
Address Auto-configuration
Item
Value setting
Description
Auto-configuration
Unchecked by default
Check to enable the Auto configuration feature.
Auto-configuration
Type
1. Can be
selected
when
Auto-
configuration
is
enabled
2. Stateless is selected
by default
Define the selected IPv6 WAN Connection Type to establish the IPv6
connectivity.
Select
Stateless
to manage the Local Area Network to be SLAAC + RDNSS
Router Advertisement Lifetime
(Required setting): Enter the Router
Advertisement Lifetime (in seconds). 200 is set by default.
Value Range
: 0 ~ 65535.
Select
Stateful
to manage the Local Area Network to be
Stateful (DHCPv6)
.
IPv6 Address Range (Start)
(Required setting): Enter the starting IPv6 Address
for the DHCPv6 range for your local computers. 0100 is set by default.
Value Range
:
0001 ~ FFFF.
IPv6 Address Range (End)
(Required setting): Enter the ending IPv6 Address for
the DHCPv6 range for your local computers. 0200 is set by default.
Value Range
:
0001 ~ FFFF.
IPv6 Address Lifetime
(Required setting): Enter the DHCPv6 lifetime for your
local computers. 36000 is set by default.
Value Range
: 0 ~ 65535.