EW50 Industrial LTE Cellular Gateway
282
The following is the summary list for the provided profiles, and events:
(
Note
: The available profiles and events will vary depending on product model.)
Profiles (Rules):
•
SMS Configuration and Accounts
•
Email Accounts
•
Digital Input (DI) profiles
•
Digital Output (DO) profiles
•
Modbus Managing Event profiles
•
Modbus Notifying Event profiles
Managing Events:
•
Trigger Type: SMS, SNMP Trap, and Digital Input (DI).
•
Actions: Get the Network Status; or Configure the LAN/VLAN behavior, Wi-Fi behavior, NAT
behavior, Firewall behavior, VPN behavior, System Management, Administration, Digital Output
behavior, and connected Modbus devices.
Notifying Events:
•
Trigger Type: Digital Input, Power Change, Connection Change (WAN, LAN & VLAN, Wi-Fi,
DDNS), Administration, Modbus, and Data Usage.
•
Actions: Notify the administrator with SMS, Syslog, SNMP Trap or Email Alert; Change the status
of connected Digital Output or Modbus devices.
To use the event handling function, enable the event management setting and configure the event details with
the provided profile settings. You can create or edit pre-defined profiles for individual managing / notifying
events. The profile settings are separated into several items; they are the SMS Account Definition, Email
Service Definition, Digital Input (DI) Profile Configuration, Digital Output (DO) Profile Configuration, and
Modbus Definition.
Then, configure each managing / notifying event by setting the event’s trigger condition, and the
corresponding actions for the event. For each event, multiple actions can be activated simultaneously.