EW50 Industrial LTE Cellular Gateway
286
Create / Edit Digital Input (DI) Profile Rule (DI/DO support required)
Set up the Digital Input (DI) Profile rules. It supports up to a maximum of 10 profiles.
When the
Add
button is applied, the
Digital Input (DI) Profile Configuration
screen will appear.
Digital Input (DI) Profile Configuration
Item
Value setting
Description
DI Profile
Name
1. String format
2. Required setting
Specify the DI Profile Name.
Value Range
:
-1 ~ 32 characters.
Description
1. Any text
2. Optional setting
Specify a brief description for the profile.
DI Source
ID1
by default
Specify the DI Source. It could be
ID1
or
ID2
.
The number of available DI sources will depend on the product model.
Normal Level
Low by default
Specify the Normal Level:
Low
or
High
.
Signal Active
Time
1. Numeric String format
2. Required setting
Specify the Signal Active Time.
Value Range
:
1 ~ 10 seconds.
Check Interval
1. Numeric String format
2. Required setting
3. ‘0’ is set by default
Specify the check interval for the DI event. If the event condition keeps active
for a long time interval, the gateway will send repeated notify events for each
check interval.
Value Range
:
0 ~ 86400 seconds.
Note:
To prevent receiving too many notifications for the same situation, you
can adjust the check interval to a value suitable for your application.
Profile
Unchecked by default
Click
Enable
box to activate this profile setting.
Save
NA
Click the
Save
button to save the configuration.