EW50 Industrial LTE Cellular Gateway
238
SNMP Version
1.
v1
is selected by
default
Select the version for the trap
v1
The configuration screen will provide the version 1 required items.
v2c
The configuration screen will provide the version 2c required items.
v3
The configuration screen will provide the version 3 required items.
Community Name
1.
v1
and
v2c
Required
setting
2. String format: any
text
Specify the
Community Name
for this version 1 or version v2c trap.
Value Range
:
1 ~ 32 characters.
User Name
1.
v3
Required setting
2. String format: any
text
Specify the
User Name
for this version 3 trap.
Value Range
:
1 ~ 32 characters.
Password
1.
v3
Required setting
2. String format: any
text
When your
Privacy Mode
is
authNoPriv
or
authPriv
, you must
specify the
Password
for this version 3 trap.
Value Range
:
8 ~ 64 characters.
Privacy Mode
1.
v3
Required setting
2.
noAuthNoPriv
is
selected by default
Specify the
Privacy Mode
for this version 3 trap.
Selected the
noAuthNoPriv
.
You do not use any authentication types and encryption protocols.
Selected the
authNoPriv
.
You must
specify the
Authentication
and
Password
.
Selected the
authPriv
.
You must specify the Authentication, Password, Encryption and Privacy Key.
Authentication
1.
v3
Required setting
2.
None
is selected by
default
When your
Privacy Mode
is
authNoPriv
or
authPriv
, you must
specify the
Authentication
types for this version 3 trap.
Selected the authentication types
MD5/ SHA-1
to use.
Encryption
1.
v3
Required setting
2.
None
is selected by
default
When your
Privacy Mode
is
authPriv
, you must
specify the
Encryption
protocols for this version 3 trap.
Selected the encryption protocols
DES / AES
to use.
Privacy Key
1.
v3
Required setting
2. String format: any
text
When your
Privacy Mode
is
authPriv
, you must
specify the
Privacy Key
(8 ~ 64
characters)
for this version 3 trap.
Enable
Box is checked by
default
Click
Enable
to enable this trap receiver.
Save
N/A
Click the
Save
button to save the configuration. But it does not apply to SNMP
functions. When you return to the SNMP main page. It will show “Click on save
button to apply your changes” to remind the user to click the main page
Save
button.
Undo
N/A
Click the
Undo
button to cancel the settings.
Back
N/A
Click the
Back
button to return the last page.